SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMPS OPERATION SECTION FOR
VARIOUS OPTIONS.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

VIOLET

VIOLET

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)
WHITE

LAMP

*LAMP

*AC / EMERGENCY

BLACK
WHITE

BLUE

BLUE 

RED
RED

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR 

RED/BLK (+)

BLK/ORG

TYPICAL WIRING DIAGRAMS

For wiring diagrams of ballasts not shown, consult our Customer Service.

Rev. 021208
68180-041

1. ONE LAMP RAPID START BALLAST

2. TWO LAMP RAPID START BALLAST

3. TWO LAMP RAPID START BALLAST

4. THREE LAMP RAPID START BALLAST

7. ONE LAMP INSTANT START BALLAST

8. TWO LAMP INSTANT START BALLAST

9. THREE LAMP INSTANT START BALLAST

10. FOUR LAMP INSTANT START BALLAST

VIOLET

VIOLET

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE 

RED
RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMPS OPERATION SECTION FOR
VARIOUS OPTIONS.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

RED OR 

RED/BLK (+)

BLK/ORG

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMPS OPERATION SECTION FOR
VARIOUS OPTIONS.

FOR 120V INSTALLATION, CONNECT BLK/ORG.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

VIOLET

VIOLET

➂ ➂

TBTS / CHARGE

INDICATOR

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK
WHITE

BLUE/WHT

BLUE/WHT 

RED
RED

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

COMMON

A.C.

Ballast

BLUE
BLUE

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR 

RED/BLK (+)

BLK/ORG

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS 
COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMP OPERATION SECTION FOR
VARIOUS OPTIONS.

CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

RED

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR 

RED/BLK (+)

BLK/ORG

RED OR 

RED/BLK (+)

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE 

RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMP OPERATION SECTION FOR
VARIOUS OPTIONS.

CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

BLK/ORG

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMP OPERATION SECTION FOR
VARIOUS OPTIONS.

CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK
WHITE

BLUE

BLUE 

BLUE 

RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR 

RED/BLK (+)

BLK/ORG

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMP OPERATION SECTION FOR
VARIOUS OPTIONS.

CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

RED

RED

BLUE 

BLUE 

YELLOW

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR 

RED/BLK (+)

BLK/ORG

5. THREE LAMP RAPID START BALLAST

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

WHITE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

RED

RED 

RED
RED

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

COMMON

A.C.

Ballast

BLUE
BLUE

UNIT

CONNECTOR

TBTS/CHARGE

INDICATOR

VIOLET

VIOLET

EMERGENCY

BALLAST

BLACK (120V)
BLK/ORG

WHT/RED

RED OR 

RED/BLK (+)

ORANGE
ORANGE

YELLOW

YELLOW

ORG (277V)

WHT/BLK

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMPS OPERATION SECTION FOR
VARIOUS OPTIONS.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.


ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMPS OPERATION SECTION FOR
VARIOUS OPTIONS.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.

VIOLET

VIOLET

UNSWITCHED

SWITCHED OR
UNSWITCHED
LINE

COMMON

ORG (277V)

BLK (120V)
WHITE

LAMP

*LAMP

*AC / EMERGENCY

BLACK
WHITE

BLUE

BLUE 

RED
RED

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR 

RED/BLK (+)

BLK/ORG

ICE-80

CHARGE

INDICATOR

6. FOUR LAMP RAPID START BALLAST

UNSWITCHED

COMMON

WHITE

BLACK (120V)
BLK/ORG

ORG (277V)

WHT/BLK

LAMP

LAMP

 LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BROWN

BROWN

RED

RED

BLU/WHT
BLU/WHT

BLUE

BLUE/WHT

RED

YELLOW

COMMON

A.C.

Ballast

UNIT

CONNECTOR

TBTS/CHARGE

INDICATOR

VIOLET

VIOLET

EMERGENCY

BALLAST

WHT/RED

RED OR 

RED/BLK (+)

RED/WHT

BLUE
BLUE

ORANGE
ORANGE

YELLOW
YELLOW

SWITCHED OR
UNSWITCHED
LINE

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.

DO NOT MATE CONNECTOR UNTIL INSTALLATION 
IS COMPLETE AND AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER TO INSTALLATION 
INSTRUCTIONS, LAMPS OPERATION SECTION FOR
VARIOUS OPTIONS.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG.

TEST ACCESSORY LEADS-REFER TO INSTALLATION 
INSTRUCTIONS FOR PROPER POLARITY WIRING.


ICE-80

CHARGE

INDICATOR

Содержание ICE-80

Страница 1: ...ersonnel 8 The ICE 80 is suitable for mounting in the ballast compartment only 9 The ICE 80 will cold strike and operate one 28W or 54W T5 or 2 8 T8 T12 or two 2 4 T8 T12 instant start rapid start U shape or circline fluorescent lamps including energy saving and long 4 pin compact lamps for 90 minutes 10 The ICE 80 is compatible with most A C ballasts including multiple lamp as follows Magnetic ba...

Страница 2: ...ng and route the leads down the platic tube Reconnect the leads to the housing observing the proper polarity Red Black or Red lead w connector to positive red tab Push the entire assembly back into the tube until the lens collar rests against the plastic tube The plastic tube should be adjusted so that the Charge Indicator is within of the fixture lens The Charge Indicator must be visible after in...

Страница 3: ...e standby charging mode The Charge Indicator will be lit providing a visual indication that the battery is being charged Emergency Mode The A C power fails The ICE 80 senses the A C power failure and automatically switches to the Emergency Mode One or two lamps are illuminated at reduced output for a minimum of 90 minutes When the A C power is restored the ICE 80 switches the system back to the No...

Страница 4: ...ER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING BLK ORG VIOLET VIOLET SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED LAMP SELECTOR LEADS REFER TO INSTALLATION INSTRUCTIONS LAMP OPERATION SECTION FOR VARIOUS OPTIONS CONNECT BLU WHT AND RED WHT WIRES TOGETHER FOR 120V INSTALLATION CONNECT BLK ORG TO BLK FOR 277V INS...

Отзывы: