INSTALLATION INSTRUCTIONS

CAUTION:   Before installing, make certain the A.C. power is off and the ICE-80 unit connector is disconnected.

1. LAMPS OPERATED

The 

ICE-80

 can be used with most 

2

–8

′ 

lamps. Refer to the chart below for the type of lamp(s) operated and the

number of lamps to be operated in emergency mode.

*The 6

 violet leads provide the lamp selection option. The unit is shipped from the factory with the leads

disconnected and capped. When used with particular lamp types, violet leads should be connected to one another.
Refer to chart for lamp selection options.

2. MOUNTING THE ICE-80

Remove the ballast channel cover. Mount the 

ICE-80

 in the ballast channel at least 

1

/

2

 away from the A.C. ballast(s).

When battery packs are remote mounted, the remote distance can not exceed ½ of the distance from ballast to
lamp specified by the A.C. ballast manufacturer. For example, if the A.C. ballast manufacturer recommends no
more than 25

 remote distance, then the battery pack should not exceed 12½

.

 

 Under no circumstances should

the battery pack exceed a distance of 50

 from the lamp.

3. WIRING

Refer to the wiring diagrams on the back page for the appropriate wiring of lamp(s) and ballast. Install in accordance
with the National Electrical Code and local regulations. For additional wiring diagrams consult Customer Service.

4. INSTALLING THE CHARGE INDICATOR

Recessed Troffer Fixture – Select a convenient location with proper clearance in the ballast cover and drill or

punch a 

7

/

8

 hole (½

 knockout). Insert the 

7

/

8

 bushing into the hole. Push the plastic tube through the bushing.

Disconnect the leads from the 

LED

 housing and route the leads down the platic tube. Reconnect the leads to the

housing, observing the proper polarity (Red/Black or Red lead w/connector to positive (+) red tab). Push the entire
assembly back into the tube until the lens collar rests against the plastic tube. The plastic tube should be adjusted
so that the 

Charge Indicator 

is within ¼

 of the fixture lens. The 

Charge Indicator 

must be visible after installa-

tion. Refer to 

Illustration 1.

Strip Fixture – Select a convenient location on the side of the fixture so the 

Charge Indicator 

can be seen after

installation. Allow for proper clearance inside the fixture and drill or punch a ½

 hole. Disconnect the leads from the

LED

 housing. Push the 

LED

 housing into the 

1

/

2

″ 

hole until it is firmly locked in place. Reconnect the leads,

observing the proper polarity (Red/Black or Red lead w/connector to positive (+) red tab). Refer to 

Illustration 2.

OPTION 

   

LAMP TYPE

EMERGENCY 

OPERATION

*VIOLET LEADS

WIRING 

DIAGRAMS

1

2

3

4

5

2´-4´ T8/T12 Single & Bipin Pin

5´-8´ T8/T12 Single & Bipin Pin

2´-4´ T8/T12 Single & Bipin Pin

2´-4´ 28W-39W T5

2´-4´ 54W T5

One Lamp

One Lamp

Two Lamp

One Lamp

One Lamp

Connected

Disconnected

Disconnected

Connected

Disconnected

1, 2, 3, 4, 5, 6, 7, 8

1, 2, 3, 5, 6

9, 10

1, 2, 3, 4, 5, 6, 7, 8

1, 2, 3, 4, 5, 6, 7, 8

6

18W-55W Long Compact

One Lamp

Disconnected

1, 2, 3, 4, 5, 6, 7, 8

5.   INSTALLING THE TEST SWITCH

           The test switch should be mounted on the ballast channel cover of a recessed troffer, or on the side of a strip
           fixture, preferably adjacent to the charge indicator. Drill or punch a ½

″ 

mounting hole.

7/8" BUSHING

FIXTURE

BALLAST CHANNEL COVER

PLASTIC TUBE

CHARGE INDICATOR
LIGHT

FIXTURE LENS

Illustration 1

Recessed Troffer Fixture

FIXTURE

CHARGE
INDICATOR
LIGHT

(POS LEAD)
RED/BLK OR  
RED W/CONNECTOR

WHITE/RED

LEAD

+ RED

Illustration 2

Strip Fixture

ICE-80

OBSERVE PROPER POLARITY

ICE-80

Содержание ICE-80

Страница 1: ...ersonnel 8 The ICE 80 is suitable for mounting in the ballast compartment only 9 The ICE 80 will cold strike and operate one 28W or 54W T5 or 2 8 T8 T12 or two 2 4 T8 T12 instant start rapid start U shape or circline fluorescent lamps including energy saving and long 4 pin compact lamps for 90 minutes 10 The ICE 80 is compatible with most A C ballasts including multiple lamp as follows Magnetic ba...

Страница 2: ...ng and route the leads down the platic tube Reconnect the leads to the housing observing the proper polarity Red Black or Red lead w connector to positive red tab Push the entire assembly back into the tube until the lens collar rests against the plastic tube The plastic tube should be adjusted so that the Charge Indicator is within of the fixture lens The Charge Indicator must be visible after in...

Страница 3: ...e standby charging mode The Charge Indicator will be lit providing a visual indication that the battery is being charged Emergency Mode The A C power fails The ICE 80 senses the A C power failure and automatically switches to the Emergency Mode One or two lamps are illuminated at reduced output for a minimum of 90 minutes When the A C power is restored the ICE 80 switches the system back to the No...

Страница 4: ...ER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING BLK ORG VIOLET VIOLET SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED LAMP SELECTOR LEADS REFER TO INSTALLATION INSTRUCTIONS LAMP OPERATION SECTION FOR VARIOUS OPTIONS CONNECT BLU WHT AND RED WHT WIRES TOGETHER FOR 120V INSTALLATION CONNECT BLK ORG TO BLK FOR 277V INS...

Отзывы: