Page 2
INSTALLATION INSTRUCTIONS
CAUTION: Before installing, make certain the AC power is off.
1. MOUNTING THE ETS-DR
Integral (No Flex)
– Remove the driver channel cover. Mount the
ETS-DR
in the ballast/driver channel
at least ½
″
away from the AC driver(s).
Flex (ETS-DR-A)
– Mount the
ETS-DR-A
on or adjacent to the fixture in a position that does not interfere
with the existing AC ballast/driver or any other hardware. Extend the flex conduit to the junction box or
wireway channel and punch a
7
/8
″
hole. Feed the wires and flex connector down through the hole in the
fixture and secure in place with the flex connector nut.
2. WIRING
Refer to the wiring diagram on the back page for the appropriate wiring of the
ETS-DR
. Install in ac-
cordance with the National Electrical Code and local regulations. For additional wiring diagrams consult
Customer Service.
3. INSTALLING THE AC INDICATOR
Integral (No Flex)
– Select a convenient location with proper clearance in the ballast/driver channel
cover and drill or punch a
7
/
8
″
hole (
1
/
2
″
knockout). Insert the
7
/
8
″
bushing into the hole. Push the plastic
tube through the bushing. Disconnect the leads from the
AC Indicator
housing and route the leads
down the plastic tube. Reconnect the leads to the housing, observing the proper polarity (Yellow lead
to red marked or positive (+) red tab). Push the entire assembly back into the tube until the lens collar
rests against the plastic tube. The plastic tube should be adjusted so that the
AC Indicator
is within
¼
″
of the fixture lens. The
AC Indicator
must be visible after installation. Refer to
Illustration 1
for an
example of integral mounting in a recessed troffer fixture.
Flex (ETS-DR-A)
– Select a convenient location on the fixture so the
AC Indicator
can be seen after
installation. Allow for proper clearance inside the fixture and drill or punch a ½
″
hole. Disconnect the
leads from the
AC Indicator
housing. Push the
AC Indicator
housing into the ½
″
hole until it is firmly
locked in place. Reconnect the leads, observing the proper polarity (Yellow lead to red marked or posi-
tive (+) red tab). Refer to
Illustration 2
for an example of mounting on a downlight fixture.
7/8" BUSHING
FIXTURE
BALLAST CHANNEL COVER
PLASTIC TUBE
CHARGE INDICATOR
LIGHT
FIXTURE LENS
Illustration 1: Integral (No Flex) Mounting
Recessed Troffer Fixture
ETS-DR
Illustration 2: Flex (ETS-DR-A) Mounting
Downlight Fixture
OBSERVE PROPER POLARITY
FLEX
CEILING
TILE
LED DRIVER AND ARRAY
COMPARTMENT
TBTS
ETS-DR-A
CHARGE INDICATOR
LIGHT
AC DRIVER/BALLAST
COMPARTMENT