© ioSelect Inc.
CONFIDENTIAL
15
io
Select
EtherWave - WMR
2.0 Quick Start
2.2 Text UI Method
(See Section 6.2 for more information re the Text User Interface.)
2.21 Required Materials
·
2 EtherWave-WMR (with factory default configuration),
each with Power Adapter and Rubber Ducky An
tenna
·
1 PC with NIC (ethernet) card and COM (serial) port
with HyperTerminal (or equivalent) application
·
1 Available connection to LAN*
·
1 Crossover patchcable (ethernet)*
·
1 Diagnostic Cable
*dependent on desired test set-up
2.22 Set-Up Procedure
·
Connect a Rubber Ducky antenna to each EtherWave-
WMR.
·
Connect the Power Adapters to available 120VAC out-
lets, and to the EtherWave-WMR.
·
Connect the Diagnostic Cable to COM2 (front) of one
EtherWave-WMR and the other end to an available COM
port on the PC.
·
Run HyperTerminal (or equivalent terminal program) on
the PC and configure it for the COM port chosen above,
115200bps, 8 data bits, no parity, 1 stop bit, and no flow
control.
·
Activate the HyperTerminal connection.
·
A login prompt will appear. Enter
admin
.
·
At the password prompt, enter
admin
.
Use the supplied power adapter or
an equivalent power source.