5.  Reinsert  the  polar  scope  back  to  the  mount. 

Align  the  scope  to  original  position  and  tighten 
the set screw. If 12 o’clock mark is not on top, 
you may rotate the polar scope to adjust it. 

 

How to align Polar Scope optical axis to mount 
RA axis: 
 

If  you  are  suspecting  that  the  polar  scope  may  be 
misaligned, you may check it by putting a star in the 
center  of  the  polar  scope  reticle  cross  hairs  and 
rotating  mount’s  RA  axis.  If  the  star  stays  in  the 
center of cross hairs, the polar scope is aligned to 
the mount’s RA axis. 
 
In  the  event  the  polar  scope  optical  axis  needs  to 
be  adjusted,  you  can  do  this  procedure  at  night 
while  pointing  at  Polaris,  or  any  bright  star. 
However,  it  is  probably  easier  to  do  it  during  the 
daytime using a distant point, such as a flag pole or 
top  of  a  building  a  couple  of  hundred  yards  away, 
as  your  target.  Please  remove  the  telescope,  the 
counterweights  and  counterweight  shaft  from  the 
mount.  Aim  the  mount  to  the  object.  Use  the 
Altitude  Adjustment  Knob  and  Azimuth  Adjustment 
Knob to center the object. 
 
1.  Remove DEC axle cover and polar scope LED. 

 

2.  Using a 5mm hex key to release four hex head 

screws  that  hold  the  DEC  unit  in  place.  One 
screw  needs  be  accessed  through  the  hole  on 
DEC unit. 

 

 
3.  After  fully  releasing  these  screws,  gently  pull 

the  DEC  unit  away  from  the  RA  axle  to 
separate it from the mount. The polar scope will 
be fully exposed. 

 

 
4.  Mount the mount onto the tripod.  

 

5.  Align  the  polar  scope  following  the  procedures 

below: 

 

 

 

a.  Release RA Gear Switch and rotate the RA 

unit  to  right  side.  Lock  the  Gear  Switch. 
Adjust  azimuth  and  latitude  adjustment 
knobs  to  center  the  aligning  object  in  the 
polar scope. 
 

b.  Release  the  RA  Gear  Switch  again.  Rotate 

the  mount  180º  to  bring  the  RA  unit  to  the 
left side. Relock the RA Gear Switch. Bring 
the object half the distance to the center by 
adjusting  the  reticle  adjustment  set  screws 
using a 2mm hex key. Keep in mind that the 
image  in  the  finder  is  inverted.  Loose  one 
screw  first,  then  tighten  the  other  screw(s). 
Only loose/tighten one screw at a time and 
a  few  turns  each  time  to  avoid  the  reticle 
totally  lost  its  position.  It  may  take  a  few 
minutes  to  familiarize  yourself  with  the 

x

x

Rotate

Rotate

Center the object

Bring the object 
half the distance 
to the center

x x

x x

Rotate

Rotate

Center the object

Bring the object 
half the distance 
to the center