![ionGen XANTREX 3000 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/iongen/xantrex-3000/xantrex-3000_installers-manual_2087547014.webp)
Solar Diagram
LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com
12
The Victron Smart MPPT solar charge controller uses maximum power point tracking that optimizes the match between the solar
array and the battery bank. It converts the higher voltage DC output from the solar panels down to the lower voltage needed to
charge the batteries. The PV solar array is connected to the MPPT charger with a circuit breaker (not supplied). The specified
circuit breaker is only rated at 48VDC; if your PV solar array has an open circuit voltage that is higher, then another circuit breaker
with a higher voltage rating must be substituted.
The charger is connected to the positive distribution buss via a 40A fuse. The fuse and wire sizes are based on the Victron MPPT
100/30 charge controller, if a larger controller is used then the fuse and wire sizes should be increased as required.
Using the VictronConnect App on your smartphone, you can connect via Bluetooth and remotely control and monitor the Smart
solar MPPT charger.