Solar Diagram
LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com
15
The Victron Smart Solar MPPT solar charge controller uses maximum power point
tracking that optimizes the match between the solar array and the battery bank. It
converts the higher voltage DC output from the solar panels down to the lower
voltage needed to charge the batteries. The PV solar array is connected to the MPPT
charger with a circuit breaker (not supplied). The specified circuit breaker is only
rated at 48VDC; if your PV solar array has an open circuit voltage that is higher,
then another circuit breaker with a higher voltage rating must be substituted.
The charger is connected to the positive distribution bus via a 40A fuse. The fus
e
a
nd wire sizes are based on the Victron MPPT 100/30 charge controller, if a larger
controller is used then the fuse and wire sizes should be increased as required.
Using the VictronConnect App on your smartphone you can connect via blue tooth
and remotely control and monitor the Smart Solar MPPT charger.