SEF100-SEF200

Heavy Duty Sewage Pumps

OPERATION MANUAL

Dated: 08/09/2016

Document Name: SEF100-SEF200_OM

Page 5 of 12

Register your product at www.ionproducts.net

WARNING: 

Servicing should be performed 

only by an authorized service center.

Always disconnect the pump from power source 

before handling or making any adjustments. Always 

wear rubber boots when there is water on the floor and 

you must unplug the pump or make any adjustments.

WARNING: 

A clearance under the pump for 

entrance of sewage solids must be a 

minimum of 2 inches to a maximum of 3.5 inches.

The sump or basin shall be sealed and vented in 

accordance with local plumbing codes. This pump 

is  designed  to  pump  domestic  wastewater,  non-

explosive and non-corrosive liquids and shall NOT 

be  installed  in  locations  classified  as  hazardous  in 

accordance with the National Electrical Code (NEC) 

ANSI/ NFPA 70 or Canadian Electric Code (CEC). 

The pump should never be installed in a trench, ditch, 

or hole with a dirt bottom. The legs will sink into thedirt 

and the suction will become plugged.

These pumps are usually installed in concrete 

or  fiberglass  basins  with  the  lift-out  rail  system. 

Instructions for installing rail system are furnished 

with rail package.

If pump is not installed with lift-out rail system it must 
be  properly supported on legs and connected to 

discharge pipe so that space is provided under pump 

for entrance of sewage. Pump inlet should not be 

closer than 2 inches from bottom of sump.

It is not generally desirable to install these pumps 

without the rail system except on special O.E.M. 

packaged systems. Check valves should always be 

installed along with shut-off valves. This allows for 

easier service and prevents backflow into basin.

Starting Pump After Installing in Sump 

Before lowering pump into basin, connect power lines 

and start motor. Impeller should turn counterclockwise 

when looking at impeller.

WARNING: 

Disconnect all power and control 

wires to motor at control panel before starting 

disassembly operation. Never rely on opening 

circuit breaker only.

CAUTION: 

Operating pump builds up heat 

and pressure; allow time for pump to cool to 

room temperature.

s

PecIfIcatIons

 (

contInued

)

Description:

To  pump  domestic, 

commercial and light industrial 

sewage

Physical Data:

Discharge Size: 2” Flanged w/ 3” NPT adapter
Impeller Type: Vortex, Cast Iron

Cable Length: 20’

Liquid Handling:

Solids Size: 2”

Acceptable Ph Range: 6-8

Temperature:

Maximum Stator: 266°F
Maximum Liquid Temp.: 104°F - Intermittent

Technical Data:

Power Cord Type & Size: 

• 

SEF100M1Ø-20 - SOW/SOOW 14AWG/3C

• 

SEF200M1Ø-20 - SOW/SOOW 12AWG/3C

• 

SEF100M 3Ø-20 - SOW/SOOW 14AWG/4C

• 

SEF200M 3Ø-20 - SOW/SOOW 14AWG/4C

Motor Housing: Cast Iron
Volute: Cast Iron

Impeller: Cast Iron

Motor Shaft: SS430
Hardware: SST
“O” Rings: NBR

Seals: Single Mechanical Carbon Ceramic
Upper Bearing: 6202

Lower Bearing: 6203

Содержание SEF100M03

Страница 1: ...operator that the failure to follow an instruction may damage the pump and or the system Safety Warnings CAUTION Read these safety warnings first before installing servicing or operating any pump Befo...

Страница 2: ...RNING Installation wiring and junction connections must be in accordance with the National Electric Code and all applicable state and local codes Requirements may vary depending on usage and location...

Страница 3: ...Never handle connected power cords with wet hands Never let cords or plugs lie in water outside the pit These pumps are offered in a three phase and single phase wiring configuration Voltages will va...

Страница 4: ...MFG Date 3 Phase Models Phase Amps L1 2 Volts L1 2 HP Amps L2 3 Volts L2 3 SN Amps L3 3 Volts L3 3 Model HP Volt Ph Nema Start Code FLA Cord Size Cord Type Cord O D Inches SEF100M21 1 60 230 1 1750 1...

Страница 5: ...egs and connected to discharge pipe so that space is provided under pump for entrance of sewage Pump inlet should not be closer than 2 inches from bottom of sump It is not generally desirable to insta...

Страница 6: ...oper motor rotation can result in poor pump performance and can damage the motor and or pump Identification Plate Note the numbers on the pumps identification plate and record in this manual for futur...

Страница 7: ...tags or labels have been removed 5 Used in a heavy grease application 6 Used in applications exceeding the designed temperature range of 32 104 degrees F Troubleshooting Pump does not run and or just...

Страница 8: ...091SW1027 091SW1027 SCREW 3 6 091SW1028 091SW1028 091SW1028 091SW1028 WASHER 4 1 091SWF104 091SWF204 091SWF231 091SWF241 STATOR ASSEMBLY 5 4 091SW1029 091SW1029 091SW1029 091SW1029 SCREW 6 2 091SW103...

Страница 9: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 9 of 12 Register your product at www ionproducts net Exploded View 1 2 3 4 5 6 7 8 9 10 11...

Страница 10: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 10 of 12 Register your product at www ionproducts net Notes...

Страница 11: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 11 of 12 Register your product at www ionproducts net Notes...

Страница 12: ...correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unl...

Отзывы: