background image

SEF100-SEF200

Heavy Duty Sewage Pumps

OPERATION MANUAL

Dated: 08/09/2016

Document Name: SEF100-SEF200_OM

Page 1 of 12

Register your product at www.ionproducts.net

I

ntroductIon

Thank you for purchasing an Ion

®

 Technologies 

heavy duty sewage pump. Take the time to read the 

instructions carefully before using this appliance. We 

strongly recommend that you keep this instruction 

manual in a safe place for future reference. 

Check the nameplate for your pump’s specification, 

refer to the table list.

Be careful not to exceed the given specifications in 

the use of your pump.

Each pump is individually factory tested to ensure 

proper performance. Closely following these 

instructions will eliminate potential operating problems 

assuring years of trouble-free service.

Most accidents can be avoided by using common 

sense.

IMPORTANT:  Ion

®

 Technologies is not responsible 

for losses, injury or death resulting from failure to 

observe these safety precautions, misuse, abuse 

or misapplication of pumps or equipment.

M

arks

 & M

eanIngs

CAUTION: 

Keep the pump equipment out of 

the reach of children! Warns that the failure to 

follow the directions given could cause serious risk to 

individuals or objects.

WARNING: 

This sign warns the operator that 

the failure to follow an instruction may damage 

the pump and/or the system.

s

afety

 W

arnIngs

CAUTION: 

Read  these  safety  warnings  first 

before  installing,  servicing,  or  operating  any 

pump.

Before Installation

This manual contains important information for the safe 

use of this product. Read this manual completely and 

follow the instructions carefully. Reasonable care and 

safe methods relating to the installation and operation 

of this product should be practiced. Check local codes 

and requirements before installation.

WARNING: 

Risk of Electrical Shock or 

Electrocution. May result in serious injury or 

death  or  fire  hazard.  Installer  must  disconnect  all 

electrical  sources  prior  to  installation,  handling  or 

servicing.  Only  qualified  personnel  may  install  this 

system. NFPA 70/National Electric Code (NEC) or 

local codes must be followed. System must be properly 

grounded according to NEC. Do not lift pump by power 

cord.

WARNING: 

Risk of Fire or Explosion. Do not 

smoke  or  use  open  flames  in  or  around  this 

system. This system is not intended for use in 

hazardous  locations  per  NFPA  70  National  Electric 

Code. Do not pump flammable liquids. Consult factory 

for  optional  equipment  rated  for  hazardous  location 

use.

CAUTION: 

Rotating machinery, 

amputation or severe lacerations can 

result. Keep clear of suction and discharge 

openings. DO NOT insert fingers into pump 

with power connected. 

Risk of serious cutting or 

Содержание SEF100M03

Страница 1: ...operator that the failure to follow an instruction may damage the pump and or the system Safety Warnings CAUTION Read these safety warnings first before installing servicing or operating any pump Befo...

Страница 2: ...RNING Installation wiring and junction connections must be in accordance with the National Electric Code and all applicable state and local codes Requirements may vary depending on usage and location...

Страница 3: ...Never handle connected power cords with wet hands Never let cords or plugs lie in water outside the pit These pumps are offered in a three phase and single phase wiring configuration Voltages will va...

Страница 4: ...MFG Date 3 Phase Models Phase Amps L1 2 Volts L1 2 HP Amps L2 3 Volts L2 3 SN Amps L3 3 Volts L3 3 Model HP Volt Ph Nema Start Code FLA Cord Size Cord Type Cord O D Inches SEF100M21 1 60 230 1 1750 1...

Страница 5: ...egs and connected to discharge pipe so that space is provided under pump for entrance of sewage Pump inlet should not be closer than 2 inches from bottom of sump It is not generally desirable to insta...

Страница 6: ...oper motor rotation can result in poor pump performance and can damage the motor and or pump Identification Plate Note the numbers on the pumps identification plate and record in this manual for futur...

Страница 7: ...tags or labels have been removed 5 Used in a heavy grease application 6 Used in applications exceeding the designed temperature range of 32 104 degrees F Troubleshooting Pump does not run and or just...

Страница 8: ...091SW1027 091SW1027 SCREW 3 6 091SW1028 091SW1028 091SW1028 091SW1028 WASHER 4 1 091SWF104 091SWF204 091SWF231 091SWF241 STATOR ASSEMBLY 5 4 091SW1029 091SW1029 091SW1029 091SW1029 SCREW 6 2 091SW103...

Страница 9: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 9 of 12 Register your product at www ionproducts net Exploded View 1 2 3 4 5 6 7 8 9 10 11...

Страница 10: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 10 of 12 Register your product at www ionproducts net Notes...

Страница 11: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 11 of 12 Register your product at www ionproducts net Notes...

Страница 12: ...correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unl...

Отзывы: