Ion Technologies Sumpro

®

Battery Back-Up

OPERATION MANUAL

Dated: 08/18/2017

Document Name: SUMPRO_100_OM

Page 7 of 12

www.ionproducts.net

Reserve Power (total hours of operation)

Duty Cycle (% of time running)

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 20 25 30

100

90

80

70

60

50

40

30

20

10

0

Performance curve results using a 3/4 HP pump with 

a 7.5 FLA and (2) Metropolitan Power Plus model 

31P-36 batteries.

Warranty Is Void If...

1.  Power cord has been cut or the grounding 

prong has been removed.

2.  Unit has been used in an outdoor application.

3. 

Batteries not meeting the above specifications 

have been used.

4.  Unit has been submerged in water.

5.  Unit has been tampered with in any manner 

not described in the above instructions.

6.  Unit has been disassembled by the customer.

7.  Unit has been applied to products exceeding 

the maximum capacity of the Unit, i.e., a pump 

other than the one supplied with the unit or 

more than one pump.

8.  Unit has been applied to the wrong voltage.

9.  Any labels or cord tags have been removed.

Replacing Batteries

Wear full eye protection and  protective clothing.

When replacing the batteries, use the same type and 

size batteries. See battery requirements (Page 2).

CAUTION

: The electrolyte is a dilute sulfuric 

acid that is harmful to the skin and eyes. It is 

electrically conductive and corrosive. The following 

procedures should be observed:

•  Do not lay tools or metal objects on top of the 

batteries

•  Use tools with insulated handles

1.  Unplug the unit from the wall.

2.  Follow the Installation Instructions found on 

page 3 of this manual, starting with step 8 and 

working back to step 1.

3.  Remove and safely dispose of old batteries.

4.  Install new batteries per the  installation 

instructions on page 3.

Technical Specifications

Model

100

A.C. Lower Voltage Limit 

98 VAC ± 5V

Output Voltage with Full Load

85-135V ± 10V

Maximum Output Current

12 FLA

Battery Lower Voltage Limit

18.5V ± 0.3V

Main Output Frequency

60 Hz

Overload

125 ± 3% (With Auto 

Reset Function)

Alarm Contact

RJ11 Connection, 

Normally Closed Dry 

Contact

Alternative DC Inputs

24VDC, 20A max

Содержание Sumpro

Страница 1: ...the grounding prong from the power cord 3 Do not smoke use sparkable electrical devices or open flame when working on this unit 4 Do not install Unit in locations classified as hazardous per N E C AN...

Страница 2: ...ilute sulfuric acid that is harmful to the skin and eyes It is electrically conductive and corrosive The following procedures should be observed a If electrolyte contacts the skin wash it off immediat...

Страница 3: ...nd to keep the unit off the floor A dedicated 15A receptacle circuit is recommended 3 Assembly Set the battery box in place making sure that the openings will be facing the back of the head unit Once...

Страница 4: ...18 2017 Document Name SUMPRO_100_OM Page 4 of 12 www ionproducts net A Figure A POSITIVE BATTERY LEAD AND TERMINAL NEGATIVE BATTERY LEAD AND TERMINAL ALTERNATIVE DC INPUT ACCESS COVER BATTERY BOX MOUN...

Страница 5: ...tructions in the controller manual The controller will be plugged into the Sumpro instead of the wall outlet If connecting a home alarm system to the Sumpro make the connection to the 6P6C RJ11 jack l...

Страница 6: ...ence has NOT been pressed b Solid when unit is running off inverter and silence has been pressed c Off when unit is operating off of AC Line 3 Alarm Red LED a Blinks when alarm condition occurs and si...

Страница 7: ...as been applied to the wrong voltage 9 Any labels or cord tags have been removed Replacing Batteries Wear full eye protection and protective clothing When replacing the batteries use the same type and...

Страница 8: ...rews are tightened to 75 pound inches 4 Check fuse link for blown fuses The system is stuck in a fault that won t clear 1 Reboot the system a While in AC mode disconnect the positive red wire from the...

Страница 9: ...nput Voltage LOST The unit has detected a loss of AC power from the utility and has switched to DC mode The unit must detect good AC voltage before switching back to AC mode 3 AC Input Voltage UNDERVO...

Страница 10: ...into a fault condition and has suspended all operations The display shows time left before operations can begin again Normal operation will resume after the timer expires 9 Sumpro Status INVERT SUSPEN...

Страница 11: ...t and send back to Metropolitan Ind Warranty Department P O Box 7266 Romeoville IL 60446 Or to register online go to www ionproducts net Sumpro Warranty Registration Card To register your purchase ple...

Страница 12: ...ect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until...

Отзывы: