Contents 

 

 

 

 

 

 

 

 

 

 

 

 

 

Declaration of conformity ............................................................................................................................... 3

 

Principle of Operation ..................................................................................................................................... 5

 

Quality Assurance .......................................................................................................................................... 5

 

Disposal ......................................................................................................................................................... 5

 

Responsibility For Use ................................................................................................................................... 5

 

Getting Started ................................................................................................................................................ 6

 

Packing List ................................................................................................................................................... 6

 

Installation ....................................................................................................................................................... 7

 

Electrical Installation ...................................................................................................................................... 7

 

15V power ...................................................................................................................................................... 7

 

Flow Fail Switch ............................................................................................................................................. 7

 

TVOC  Overview ............................................................................................................................. 8

 

TVOC  Connections ........................................................................................................................ 9

 

DIN Rail Terminations ................................................................................................................................... 10

 

Service & Maintenance ................................................................................................................................. 11

 

Service Intervals .......................................................................................................................................... 11

 

Important note for service of the TVOC; ...................................................................................................... 11

 

Weekly ......................................................................................................................................................... 11

 

Biannually .................................................................................................................................................... 11

 

Annually ....................................................................................................................................................... 11

 

Tubing .......................................................................................................................................................... 11

 

Spare Parts List ............................................................................................................................................. 12

 

Maintenance ................................................................................................................................................... 12

 

Flow Fail Switch ........................................................................................................................................... 12

 

Manual log ...................................................................................................................................................... 13

 

Содержание TVOC System Plus

Страница 1: ...Part number 871026 Unrivalled Detection www ionscience com TVOC System Plus Instrument User Manual V1 2...

Страница 2: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 2 of 13 Unrivalled Detection www ionscience com...

Страница 3: ...rical equipment for measurement control and laboratory use EMC Requirements Class B and General Immunity Other Standards BS EN ISO 9001 2000 Quality Management Systems Requirements BS EN 61010 1 2001...

Страница 4: ...ility For Use 5 Getting Started 6 Packing List 6 Installation 7 Electrical Installation 7 15V power 7 Flow Fail Switch 7 TVOC System Overview 8 TVOC System Connections 9 DIN Rail Terminations 10 Servi...

Страница 5: ...or similar sampling tubing is used so that any VOC s are not absorbed into the tubing walls The 4 20mA analogue output is wired directly from the TVOC instrument to a DIN rail mounted connector for ea...

Страница 6: ...ystem Plus box should include Item Description Qty 1 TVOC instrument complete fitted 1 2 User manual TVOC Instrument 1 3 User manual System Plus Supplement 1 4 Mini Pump fitted 1 5 Water Trap Filter f...

Страница 7: ...external 15V DC supply must be fused at 1A before entering the cabinet The supply is connected to the internal terminals see drawing below 15V power 15V positive terminal number 8 15V zero to termina...

Страница 8: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 8 of 13 Unrivalled Detection www ionscience com Installation TVOC System Overview...

Страница 9: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 9 of 13 Unrivalled Detection www ionscience com Installation TVOC System Connections...

Страница 10: ...TVOC SYSTEM PLUS MANUAL Ion Science Ltd Page 10 of 13 Unrivalled Detection www ionscience com DIN Rail Terminations...

Страница 11: ...mpled gas length of sample line being used etc etc As a guide we would recommend the following Service and Maintenance program Weekly Water Trap Filter check and remove any water in the unit To disass...

Страница 12: ...mm OD 4mmID TUBE 06 Maintenance Flow Fail Switch The flow switch is factory pre set to fail at 200cc s This setting can be checked with a Multimeter using the SET terminal on the flow switch which sho...

Страница 13: ...L Ion Science Ltd Page 13 of 13 Unrivalled Detection www ionscience com Manual log Manual Version Amendment Date updated Instrument Firmware PC Software TVOC System Plus Manual V1 2 Manual Reformatted...