5.5.5 Calculate the real detection distance
The actual detection distance
DalarmReal
is the value to be entered in the
Configuration
page of the Inxpect
Safety application.
DalarmReal
indicates the maximum distance between the sensor and the object to be detected.
5.6 Outdoor installations
5.6.1 Position exposed to precipitation
If the sensor installation position might be exposed to precipitation that can cause undesired alarms, it is
recommended to take the following precautions:
l
make a cover to protect the sensor from rain, hail or snow
l
position the sensor so that it does not frame the ground where puddles might form
5.6.2 Recommendations for covering the sensor
Below are some recommendations for creating and installing a sensor cover:
l
height from sensor: 15 cm
l
width: minimum 30 cm, maximum 40 cm
l
protrusion from the sensor: minimum 15 cm, maximum 20 cm
l
water outflow: at the sides or behind but not in front of the sensor (the cover should be arched and/or
tilted backwards)