Goodrive300-21 integrated machine for air compressor
Function description
-
23
-
5 Function description
"○" indicates that the value of the parameter can be modified when the inverter is in stopped or
running state.
"
◎
" indicates that the value of the parameter cannot be modified when the inverter is in running state.
"●" indicates that the value of the parameter is detected and recorded, and cannot be modified.
(The inverter automatically checks and constrains the modification of parameters, which helps
prevent incorrect modifications.)
5.1 Function code instruction
Function
code
Name
Description
Default Modify
P00.00
Speed control mode
0: Sensorless vector control (SVC) mode 0
(for AM, SM)
1: SVC mode 1 (for AM)
2: V/F control
AM-asynchronous motor
SM-synchronous motor
0
◎
P00.01
Channel of running
commands
0: Keypad (the indicator is off)
1: Terminal (the indicator blinks)
2: Communication (the indicator is on)
0
○
P00.02
Communication
mode of running
commands
0: MODBUS communication channel
1
–3: Reserved
0
○
P00.03
Max. output
frequency
P00.04
–600.00Hz (400.00Hz)
50.00Hz
◎
P00.04
Upper limit of
running frequency
P00.03
–P00.05 (Max. frequency)
Setting range: P00.03
–P00.06
50.00Hz
○
P00.05
Lower limit of
running frequency
0.00Hz
–P00.04 (Upper limit of running
frequency)
0.00Hz
○
P00.06
Setting channel of A
frequency command
0: Keypad
1: Analog P1-setting
2: Reserved
3: Analog P2-setting
4: Reserved
5: Reserved
6: Multi-step speed running
7: PID control
8: MODBUS communication
0
○
P00.07
Setting channel of B
frequency command
2
○
Содержание GD300-21-011G-2
Страница 1: ...Goodrive300 21 Series Dual inverter Integrated Machine for Air Compressor...