Goodrive600 series high-performance multifunction VFD
Basic operation guidelines
-76-
Function code
Name
Description
Default
P02.19
Rated current of SM 1
0.8
–6000.0A
Model
depended
P02.20
Stator resistance of SM 1 0.001
–65.535Ω
Model
depended
P02.21
Direct-axis inductance of
SM 1
0.01
–655.35mH
Model
depended
P02.22
Quadrature-axis
inductance of SM 1
0.01
–655.35mH
Model
depended
P02.23
Counter-emf constant of
SM 1
0
–10000
300
P05.01
–P05.04
Multifunction digital input
terminal
(S1
–S4)
function selection
35: Switch from motor 1 to motor 2
/
P08.31
Switching between motor 1
and motor 2
0x00
–0x14
Ones place: Switchover channel
0: Terminal
1: Modbus communication
2: CANopen communication
3: Ethernet communication
4: PROFINET communication
5: PROFIBUS communication
Tens place: indicates whether to enable
switchover during running
0: Disable
1: Enable
00
P12.00
Type of motor 2
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
P12.01
Rated power of AM 2
0.1
–3000.0kW
Model
depended
P12.02
Rated frequency of AM 2
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
P12.03
Rated speed of AM 2
1
–60000rpm
Model
depended
P12.04
Rated voltage of AM 2
0
–1200V
Model
depended
P12.05
Rated current of AM 2
0.8
–6000.0A
Model
depended
P12.06
Stator resistance of AM 2 0.001
–65.535Ω
Model
depended
P12.07
Rotor resistance of AM 2
0.001
–65.535Ω
Model
depended
P12.08
Leakage inductance of AM
2
0.1
–6553.5mH
Model
depended
P12.09
Mutual inductance of AM 2 0.1
–6553.5mH
Model
depended
P12.10
No-load current of AM 2
0.1
–6553.5A
Model
depended
P12.15
Rated power of SM 2
0.1
–3000.0kW
Model
depended
P12.16
Rated frequency of SM 2
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz