Keep away from flames and flammable/explosive substances to avoid fire or explosions. Never pour
flammable liquids such as gas, perfume etc. into the fog machine.
Keep product and fog liquid out of reach of children. Use only under adult supervision.
Do not spray in the direction of flames or people. Stay at least 20 inches
(50cm) from the nozzle at the front of the unit.
Do not obstruct the nozzle.
Do not open unit. No user serviceable parts inside, please refer to your
vendor. Only an electrician can change the power cord.
Clean unit before storage to avoid damages.
OPERATING INSTRUCTIONS
1. Remove all packaging before use. Please contact the store if you find any broken or missing parts.
2. Place the unit on a flat, level surface.
3. Unscrew the lid on the reservoir tank towards the back of the Fog Machine and pour the Fog Liquid
inside. Do not spill Fog Liquid onto the unit. Do not overfill. If liquid gets into Fog Machine, allow unit to
dry completely before plugging in. Do not cut, pinch, or break the tube connected through the tank lid.
Close the lid to the reservoir tank tightly. Always make sure there is enough Fog Liquid in the tank
before using the Fog Machine.
4. Plug the Receiver into the back of the Fog Machine. Now connect the unit with the proper power
supply (120VAC).
5. Warm up time is approximately 3.5 – 5 minutes. When fully heated, the light on the Receiver will turn
on and the Fog Machine will be ready to produce fog.
6. Extend the antenna on the Remote and slide up the cover to expose the “ON/OFF” buttons. Push “ON”
to produce fog, and press “OFF” to stop the flow of fog.
7. Unplug the unit before refilling the fog machine, and follow the directions in Step 3.
8. Unplug the unit when not in use.
ADDITIONAL INFORMATION
It is normal for condensation to appear on the nozzle of the Fog Machine.
A small amount of fog may spray during or after operation.
The unit will have to reheat after long bursts of use. The unit will stop operation for a short period in
order to heat up to operating temperature again.While this is happening, fog cannot be produced. The
light on the remote will turn on again when the unit is ready to generate more fog.
MAINTENANCE & SERVICING
Note:
Use of fogger liquids not included or those other than SVI Fog Liquid are not recommended and
may result in blockage, leakage, or other damage to the unit.
INSPECTION:
Before each use, check unit for any cracks in the enclosure, remote control, cords, and plugs.
Make sure there are no exposed wires. Do not use if any of the above conditions are found.
CLEANING:
Should you experience low fog output after many hours of continuous operation or after the machine
has been idle or in storage for a long time, it is recommended to run a cleaning solution through the
system to prevent the accumulation of particles in the heating element.
a. While the unit is unplugged and cool, empty all Fog Liquid from the machine and replace with a
fog machine cleaning solution in the tank. SVI Fog Machine Cleaning Fluid (not included) is
recommended. Plug unit in and allow to warm as usual.
b. Run unit in a well-ventilated area until tank is empty.
c. Cleaning is now complete. Unplug and refill with a water-based Fog Liquid once cool.