When the LED control input is pulled low, the GREEN LED will 

be ON and the RED LED will be OFF.  When the input goes 

high the RED LED is ON and the GREEN LED is OFF.  The RED 

or GREEN LED will flash with each key press. The LED control 

input is pulled to the in5v with a 2.2K resistor.
The data is sent at 2 millisecond. per bit with a pulse duration 

of 70 μsec. A Buzzer beeps with each key press.

Data Format

 

PIN  data in 8 Bit burst output format:
Each Key press generates the defined 8 bit Output as shown:

 

Card data  26 WIEGAND output format.

 

              P S S S S S S S    N N N N N N N N N N N N N N N   P
BIT 

1 2  

                    9   10 

                  25 26

BIT 

1 is an even parity for the following 12 bits.  

 

The sum of bits 1-13 is even. 

BITS 

2-9 are the  F/C the card presented from  

 

000 to 255. 

BITS 

10-25 this is the card number presented.  

 

Leading 0’s are added as required. Bit 10  

 

is most significant. 

BIT 

26 Odd parity over previous 12 bits. The sum of  

 

bits 14-26 is odd.  

EXAMPLE:

  A card code of 123 entered:

1  0 0 0 0 0 1 0 0    0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 1    1    

(F/C 004)

26 BIT WIEGAND SPECIFICATIONS: 

The data is sent at 2 msec per bit with a pulse duration of  

70 μsec. A Buzzer beeps each time card is presented.

1.  

Blue Wire - 

PRESSING any key on the keypad will generate  

  a 30 second 0.25 amp intermittent duty grounding output.
2.  

Orange Wire -  

When the Hold Line, Orange wire, is pulled  

  “low”, any codes entered on the keypad are stored in the   

  buffer. When the Hold Line is released to logic “high” – the 

   buffered code data is sent.
2.  

Grey Wire -  

When  the photodiode senses ambient light the  

  Grey wire is pulled “LOW”. An error code is generated by any  

  of the following:
  a) Pressing the # key with no preceding digits;
  b) Pressing any number of only zero’s prior to pressing  

    the # key, or;
  c) Pressing 65,535 or any number above 65,535.  

    An Error Code will send all binary 1’s to your panel.
    DO 

NOT

 Program your panel to accept code number 65,535.

 

KEY

OUTPUT

KEY

OUTPUT

0

11110000

6

10010110

1

11100001

7

10000111

2

11010010

8

01111000

3

11000011

9

01101001

4

10110100

*

01011010

5

10100101

#

01001011