www.invisiblefence.com
5
ICT250, ICT725 and ICT750
1. Remove and discard the green ground wire connecting the circuit board to the
electrical outlet. (See figure 2)
2. Remove and discard the one (ICT725) or two (ICT250 and ICT750) LP-cards
from the blue sockets on the transmitter circuit board. (See figure 2)
3. Insert the jumper-card supplied into each empty blue socket.
4.
Refer to steps 2 – 6 of the LP-4100 / LP-4200 manual to complete installation.
Figure 2
NOTE:
Additional twisted wire may be required when upgrading to this new lightning
protection device. If additional wire was not included in your kit, please notify your local
Invisible Fence Brand dealer.
CAUTION:
Do not install this device if there is not at least 10 meters (30 feet)
or more of wire between the electrical outlet and electrical service panel.
Green
Ground Wire
LP-card (Remove)
Jumper-card
(Insert)