Invicta pharos Скачать руководство пользователя страница 3

   PAGE 3

OBLICA

 | PHAROS INSTALLATION AND USER MANUAL

2. PRE-INSTALLATION

Congratulations on your purchase of the Pharos. This appliance should be installed and checked by a qualified 
professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or 
concerns please contact Oblica on 03 9416 0400. 

The installation process is outlined below:
 

– Determine position of firebox and flue carefully observing the clearances described within this section

 

– Install the external flue

 

– Install the internal flue and engage the firebox

 

– Ensure the floor has adequate protection

CAUTION:

Using components or parts other than those provided by the manufacturer or modifying the specification of 
components may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the 
first instance. 
 

WARNING: 

•  The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the 

relevant building code or codes.

•  Any modification of the appliance that has not been approved in writing by the testing authority 

will be in breach of the approval granted for compliance with AS/NZS 4013.

•  Once the flue has been installed and approved by a professional installer, the flue must not be 

modified in any way.

Содержание pharos

Страница 1: ...PHAROS MODEL SPECIFICATIONS 1 TECHNICAL DATA 2 2 PRE INSTALLATION 3 3 INSTALLATION 5 4 OPERATION 9 5 TESTING 10 Keep for future use...

Страница 2: ...AL DATA WEIGHT AND DIMENSIONS Dimensions Firebox W531 x H1250 x D530mm Firebox weight 167kg Flue kit Standard 7 9 11 DETERMINED UNDER TEST CONDITIONS Nominal thermal output 9kW Efficiency Australian T...

Страница 3: ...l flue and engage the firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification of components may...

Страница 4: ...ith the application of heat shielding to walls in accordance to the Australian Building Code For information on heat shielding please contact our office on 03 9416 0400 or email info oblica com au IMP...

Страница 5: ...HAROS INSTALLATION AND USER MANUAL 3 INSTALLATION 3 1 Typical flue kit installation Cowl Chinaman Hat 9 Outer Case 11 Outer Case 9 Outer Case 11 Outer Case 7 Active Flue 7 9 Flue CEILING RING RUBBER D...

Страница 6: ...he triple skin flue is installed as per Australian standards see diagrams below The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distan...

Страница 7: ...combustiblefinishescanbeappliedtothefloorprotector tiles steelsheet lightconcrete etc If the combustible floor is installed on concrete you can replace the combustible material with non combustible ma...

Страница 8: ...TALLATION AND USER MANUAL Non combustible finish eg tiles Concrete Combustible floor eg timber 300mm 730mm 810mm Combustible floor eg Timber Floor protector FLOOR PROTECTOR LAID ON CONCRETE 3 INSTALLA...

Страница 9: ...s to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of...

Страница 10: ...5 INVESTIGATING OFFICER Steve Marland RESULTS The Pharos solid fuel burning appliance produced an appliance particulate emissions factor of 1 2g kg and an average efficiency of 60 for all burn rates u...

Отзывы: