SCOPE OF WARRANTY 

The product comes with a standard 1-year warranty. This warranty includes all defects of design, 
components and manufacturing. The warranty is void and does not cover any defects or damages 
caused by in any of the following 

circumstances: 

Seal on the product is broken

The product has been misused, neglected, or abused

Improper transportation and delivery

The product has been used or stored in conditions outside its electrical or environmental

specifications

The product has been used for purposes other than for which it was designed

The product has been used outside its stated specifications, operating parameters and

application

Acts of third parties, atmospheric discharges, excess voltage, chemical influences, natural

wear and tear and for loss and damage in transit

Improper testing, operation, maintenance, adjustment, repair, or any modification of any kind

not authorized in writing by the supplier

The product has been connected to other equipment with which it is not compatible

Use and application beyond the definition in this manual

Application beyond the scope of applicable safety standards or grid codes

Acts of nature such as lighting, fire, storm, flood, vandalism and etc.

The right to repair and/or replace the defective product is at the supplier's sale discretion. The 
supplier is not responsible for damages beyond the scope of this warranty.

Содержание SICM16H24

Страница 1: ...INSTRUCTION MANUAL SICM8H12 SICM16H24 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE MACHINE www investsolar co za ...

Страница 2: ...to direct sunlight rainfall or snow Before performing any maintenance on the product please disconnect all power sources AC mains batteries solar panel to avoid the risk of electrical shock Do not attempt to disassemble or repair the product Only authorized personnel are allowed to perform repair While performing maintenance or cleaning especially on the batteries where hazardous liquid might be t...

Страница 3: ...e its stated specifications operating parameters and application Acts of third parties atmospheric discharges excess voltage chemical influences natural wear and tear and for loss and damage in transit Improper testing operation maintenance adjustment repair or any modification of any kind not authorized in writing by the supplier The product has been connected to other equipment with which it is ...

Страница 4: ...9 2 3 Batteries 9 2 4 PV solar string 11 2 5 Connect AC Input Cables and Loads 12 2 6 AC Input Voltage Range Selector 12 OPERATION 14 3 1 Standby Charging Mode 14 3 2 Operation Modes after powered on 15 3 3 Priority Setting Switch 16 3 4 Fault Mode 17 3 5 LCD Setting 17 SPECIFICATION 21 TROUBLESHOOTING 22 Alarm Behavior Table 23 APPENDIXA 24 APPENDIX B 29 ...

Страница 5: ...the power from AC mains if enough sunlight is present The battery can be charged by both AC mains and PV solar string with intelligent charging controller Key features Automatic line to battery switch over Built in enhanced AC charger Built in solar charger controller Configurable output source priority charger source priority charger current and soon High efficient DC to AC conversion with minimi...

Страница 6: ...1 1 Product Outlook Front Panel Power ON OFF button Setting function button LCD LED indicators Rear Panel AC input socket AC output socket PV Input terminals Battery terminals DC Fan ...

Страница 7: ...con indicates level of remaining battery capacity The icon indicates battery flow way If unit is on CC CV charging stages FAST will be lighted The icon indicates output load level If unit work on bypass mode BYPASS will be lighted Indicate PV input voltage PV input current AC input voltage Battery voltage Indicate output voltage output frequency load percentage load VA voltage watt value The icon ...

Страница 8: ... seconds Line Mode 2 charge current 3A Green solid lighting Off charge mode Green flashing as cycle 0 5s On 0 5s Off 0 5s On 4s off Yellow Battery mode Yellow solid lighting Red Overload Red flashing every 0 5 second Fault Red lighting Function Keys Function Keys Description To power on off To enter the setting mode or exit setting mode To go to the next selection page To confirm the selection in ...

Страница 9: ...al Application A typical application diagram for home and office applications is as shown below The inverter can accept AC input from AC mains and is capable of supply various loads such as fluorescent lamp fan ...

Страница 10: ... carry the inverter 2 The location of installation shall allow the user to read the LCD easily 3 Two screws shall be firstly fixed on the wall distance as shown below so that the inverter can be hung on the screws recommended screw size is M4 50 65mm 4 After mounting the inverter make sure it s firmly mounted and won t easily fall off in the event of unexpected earthquake or vibration 2 3 Batterie...

Страница 11: ...d to cover the battery terminals during the connection Check the polarity of cables before connecting to the inverter Connect the battery cables to the inverter s battery terminals as shown below Connect with single battery Make sure the battery voltage meets the inverter s specification 12V for 1000VA 1200VA modeland24V for 2000VA 2200VAmodel battery Connect with multiple batteries While connecti...

Страница 12: ...ing Selection of PV panel PV string is a connection of PV panels whose output voltage and current vary under different illumination And just like battery the PV panel can be connected in either series or parallel as per needed Please consult the supplier of PV panel so that the operational voltage and current fall within the allowed range of the inverter as set out in the specification Please do n...

Страница 13: ...aker with 80A rating shall be installed as shown below please check the polarity before connection Circuit Breaker 2 5 Connect AC Input Cables and Loads Connect the AC input cables and loads to the receptacles as shown below 2 6 AC Input Voltage Range Selector A NARROW setting Set the selector to NARROW when connected with loads which are more sensitive on voltage range With this setting the inver...

Страница 14: ...inverter s input voltage range is extended to 90 280VAC while output voltage follows input voltage Please note that the inverter s transfer time switching from Line Mode to Backup Mode gets longer as the input voltage gets low Under the circumstance connecting the inverter with loads which are sensitive to transfer time e g computer might result in power interruption ...

Страница 15: ...s called Standby Charging Mode When AC input cable and battery is connected the inverter will enter Standby Charging Mode and LCD will be turned on with the following display If PV string is also connected with enough voltage the display will be as shown below to indicate the power flow from PV string Even if AC input is absent PV power can still charge the battery and the display will be as shown...

Страница 16: ...y enter either of the operation mode according to the condition of LINE MODE1 AC input power is present but there is no PV power e g nighttime Load is supplied by AC input power directly LINE MODE 2 Both AC input and PV input are present Load is supplied by either AC input or PV input depending on the priority switch s setting ...

Страница 17: ...med an energy saving operation BACKUP MODE 1 Both AC input and PV input are absent The backup power to load comes only from battery The backup time is determined by the capacity of battery BACKUP MODE 2 AC input is absent and PV power is not enough to support loads completely The insufficient power is covered by battery The larger the PV power the less consumption from battery and therefore the lo...

Страница 18: ...e LCD display content will be changed in turns by pressing button The Select able information is switched as below order PV input voltage PV input current AC input voltage battery voltage output voltage output frequency load percentage load VA value load watt value LCD will return to default LCD display after 1 minute if users want to return to default LCD display immediately please press button 2...

Страница 19: ...oint is program 5 Utility first Utility will provide power to the loads as priority Solar and battery energy will provide power to the load only when utility power Is not available SbU Solar energy provides power to the loads as priority If solar energy is not enough to power all connected loads battery energy will supply power the load at the same time Utility provides power to the loads only whe...

Страница 20: ...A model 21V 21 5V 22V default 22 5V 23V 23 5V 24V 24 5V 6 Max charging current To configure total charging current for solar and utility chargers Max charging current utility charging current solar charging current Options in 1 K 1 2KVA model 20A 30A 40A 50A 60A default 70A 80A Options in 2K 2 2KVA model 20A 30A 40A 50A 60A default 75A 7 Max utility charging current Options in 1 K 1 2KVA model 0A ...

Страница 21: ...w DC cut off voltage will be related to load percent 10 0V for 12V model 60 load 10 5V for 12V model 60 load 20 0V for 24V model 60 load 21 0V for 24V model 60 load Setting range is from 10 0V to 12 0V for 12V model 20 0Vto 24 0V for 24V model Increment of each click is 0 2V per step 10 LED Light control LED light off LED light on default 11 Recover manufactory setting Recover enable Recover disab...

Страница 22: ...ECTION Discharge over charged over loading over temperature short circuit protection BATTERY CHARGER powered by AC CHARGING ALGORITHM 3 step charging AC CHARGING MOD 0A 5A 10A 15A 2OA selectable 0A 5A 10A 15A selectable FLOATING CHARGING VOLTAGE 13 7V 27 4V OVERCHARGING VOLTAGE 16V 32V SOLAR BATTERY CHARGER MAX PV PANEL ARRAY POWER 900W 1050W 1500W 1750W MAX PV MODE POWER RATING TO SUPPORT LOAD 50...

Страница 23: ...ance Solar is normal but Solar charger doesn t work P V reverse polarity protection Re connect the P V terminals Alarm Behavior Table Fault Description Line Mode Backup Mode Fault Code No of Beeps AC Output No of Beeps AC Output Overload 1 Vou 195V 0 OFF 0 Output RMS voltage low 2 OFF 2 Over temperature Short circuited 3 OFF 3 Fan locked 4 ON 4 OFF 4 Battery voltage high 5 ON 5 Overload 2 Vou2195V...

Страница 24: ...ge and current of the string is When connecting the above PV string in parallel the max voltage and current of the total string is In either case the total output power is Ptotal Ppanel X Number of PV panel The guideline to select and configure PV string is Itotal shall be equal or slightly larger than the max capacity of solar battery charger 50A for 1000VA 2000VA model and 60A for 1200VA 2200VA ...

Страница 25: ...e of the solar battery charger 55V for all model Total Isc of the string shall be less than the max PV input current of the solar battery charger 65A for all model Example 1 How to connect 1000VA model to PV panels with the following parameters Pmax 150W Vmp 18V Voc 21 6V Imp 8 2A lsc 8 75A 1 Max charging current is 50A 50A 8 2A 6 09 max number of PV panel in parallel is 6 2 Operating Voltage Rang...

Страница 26: ... Isc 8 75A 5 Max charging current is 60A 60A 8 2A 7 31 max Number of PV panel in parallel is 7 6 Operating Voltage Range is 16 18V One PV Panel Vmp 18V is between 16 18V max Number of PV panel in parallel is 1 7 Taking 1 2 into consideration and the optimized configuration is 6 PV panels in parallel as shown below 8 Check again the Voc and the Isc of PV string Voc of string is 21 6V 55V Max PV Inp...

Страница 27: ... 2 Operating Voltage Range is 32 36V One PV panel Vmp 30 96V is between 32 36V max Number of PV panel in parallel is 1 3 Taking 1 2 into consideration the optimized configuration is 1 PV panels in series as a string and 6 strings in parallel as shown below 4 Check again the Voc and Isc of PV string Voc of string is 1x36 6V 36 6V 55V Max PV Input Voltage OK Isc of string is 6x8 75A 52 5A 65A Max PV...

Страница 28: ... 6 Operating Voltage Range is 32 36V One PV panel Vmp 30 96V is between 32 36V max Number of PV panel in parallel is 1 7 Taking 1 2 into consideration the optimized configuration is 1 PV panels in series as a string and 6 strings in parallel as shown below 8 Check again the Voc and Isc of PV string Voc of string is 1x36 6V 36 6V 55V Max PV Input Voltage OK Isc of string is 7x8 75A 61 25A 65A Max P...

Страница 29: ...tput source priority setting 1 Setting Utility as output source Priority Utl 1 1 When utility is normal The loads connected to the product are supplied by utility power only even when solar power presents 1 2 When utility is down As soon as the utility is down the inverter enters Backup Mode and checks both solar power and battery s status If solar power is strong enough it will supply the loads i...

Страница 30: ...will not be consumed even though it s available If solar power is not enough battery will firstly come up to support the loads and after battery is low or the setting point in program 5 utility will then take over to support the loads and charge the battery 3 2 When utility is down The behavior is the same as 1 2 Advantages Disadvantages Risk The good utilization of solar power Save electricity bi...

Страница 31: ...en utility is normal Solar energy and utility will charge battery at the same time 4 2 When utility is down Solar energy will charge battery Summary Whether setting which option as charger source priority subject to purpose of installing the product In the event the product is to be installed in areas where the utility power is unstable and backup function is much important than energy saving Sola...