![Invest Solar SIC-P-M-3T24-IS Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/invest-solar/sic-p-m-3t24-is/sic-p-m-3t24-is_user-manual_2085188019.webp)
http://www.investsolar.co.za
17
19
Bulk charging voltage
(C.V voltage).
If USE is selected in
program 5, this program
can be set up
24V model: default 28.2V, 24.0V~29.2V Settable
20
Floating charging
voltage.
If USE is selected in
program 5, this program
can be set up
24V model: default 27.0V, 24.0V~29.2V Settable
21
Low DC cut-off voltage.
If USE is selected in
program 5, this program
can be set up
24V model: default 21.0V, 20.0V~24.0V Settable
24
Deliver signal to
external device when
battery voltage reaches
warning level
(When set as “Disable”)
Disable: Neutral and grounding of AC output is disconnected.
(Default)
Enable: Neutral and grounding of AC output is connected.
(only for 4kva/5kva model)