SYSTEM OVERVIEW: IV-LIGHT VENTILATION DEVICE

9

iV-Light ventilation device | Installation instructions

2.1  Construction

Figure 1: Overview of the iV-Light ventilation device

Components

Thermal accumulator insert  

(thermal accumulator and inVENTron)

Light inner cover

External termination: 

Light weather protection grille

1)

Wall sleeve

1  Weather protection grille

2  Fixing claws (2 x, pre-installed)

3  Fixing screws (2 x, pre-installed)

4  R-D160 wall sleeve

5  Recess for controller connecting 

cable

6  Thermal accumulator with insulation

7  Thermal accumulator handle

8  Standard guiding vane (45 mm)

9  Xenion reversible fan

10  Slim guiding vane (16 mm)

11  Guiding vane knob

12  BUS plug connection

13  Inner cover base plate  

(incl. ISO Coarse 60 % dust filter)

14  Inner cover panel

15  Connecting element

1) 

The description of the components of all other possible external terminations can be found in the separate installation instructions 
of the respective external termination.

A

B

D

C

A

B

C

D

1

3

5

8

11

6

2

9

1

2

7

10

13

14

15

4

12

Содержание iV-Light

Страница 1: ...www inventer eu Installation instructions iV Light Ventilation device with heat recovery...

Страница 2: ...d components Nevertheless deviations may still occur therefore no guarantee of compliance can be provided This documentation describes the functionality of the standard scope For reasons of clarity th...

Страница 3: ...the scope of supply 18 4 2 Create wall opening 19 4 3 Laying the cables to the wall opening of the ventilation device 20 4 4 Installing the wall sleeve 22 4 5 Installing the ventilation device s exter...

Страница 4: ...ates the severity of the potential hazard unless the preventive measures are taken DANGER means Imminent danger of serious injury or death WARNING means Possible danger of serious injury or death CAUT...

Страница 5: ...liability insurance association Use the equipment system exclusively for the applications that are described in this documentation and only in conjunction with components that are recommended authoris...

Страница 6: ...f the components especially the thermal accumulator NOTICE In order to avoid algae growth around the exterior closures the instructions for installation must be followed exactly apply all sealing tape...

Страница 7: ...g to the outside and or for the purpose of smoke removal smoke extraction in basements without windows Qualified personnel The equipment system may only be set up operated and cleaned in conjunction w...

Страница 8: ...ow through the thermal accumulator The unique geometry of the Xenion reversible fan effectively reduces sound transmission The standard length of the wall sleeve is 495 mm For thicker walls a wall sle...

Страница 9: ...s 2 x pre installed 4 R D160 wall sleeve 5 Recess for controller connecting cable 6 Thermal accumulator with insulation 7 Thermal accumulator handle 8 Standard guiding vane 45 mm 9 Xenion reversible f...

Страница 10: ...xtract air After 70 seconds the reversing fan changes the direction of rotation each time After the direction of rotation has changed the heat accumulator releases the stored heat energy to the incomi...

Страница 11: ...a In order to ensure the full functioning of the ventilation device throughout the entire year a temperature sensor is integrated into the Xenion reversible fan This measures the temperature of the ai...

Страница 12: ...8 Multi zone control No No Operating concept Switch Touch Operating modes Heat recovery Through ventilation OFF standard version only Heat recovery Through ventilation OFF standard version only Funct...

Страница 13: ...e function 1 8h per zone Dehumidification with variable air volume flow Dehumidification with variable air volume flow and other demand ventilation Pause function global and zonal Boost function globa...

Страница 14: ...water spray is possible Observe the specifications of VDE 0100 when choosing the installation location Minimum distances of the wall opening for the ventilation device Minimum distances to components...

Страница 15: ...tions for yourspecific external termination Standard ventilation device variant Light weather protection grille Figure 2 Dimensioned drawing of the iV Light wall opening interior view 1 Minimum distan...

Страница 16: ...wing of the iV Light ventilation device Figure 3 Sectional drawing of the iV Light ventilation device 1 Inner cover base plate 2 Connecting element 3 Filter holder 4 Inner cover panel 5 R D160 wall sl...

Страница 17: ...ner cover 1 Inner cover base plate 2 Connecting element 3 Locking hook 4 Inner cover panel 5 Filter holder 6 Interior wall fixing hole optional 7 Connecting element fixing 4 x 4 8 184 210 184 210 160...

Страница 18: ...ions variants wall sleeves for integrating the Connect controller platform and the interior closure variants please refer to the separately available installation instructions for the respective syste...

Страница 19: ...are at all uncertain Create the wall opening through core drilling Drill with core drill attachment or milling drill 180 mm additionally if flush mounted inner cover is installed chisel Requirements T...

Страница 20: ...1 5 mm House distribution ventilation sub distribution Unit communication only if the system compo nents communicate by cable otherwise radio RS485 data cable e g Type J Y ST Y 2x2x0 8 mm Easy Connect...

Страница 21: ...munication by cable RS485 data cable Cross section 0 25 0 5 mm Length max 500 m Cable NYM J wire cross section 1 5 mm Ventilation device n Control device Connect inner cover Ventilation device 1 Contr...

Страница 22: ...finished The cables to the wall opening of the ventilation device have been laid X Y D A B C Determine the exact wall thickness X D Exterior rendering incl other superstructures if applicable C Insula...

Страница 23: ...Accumulation ofcondensation water in thewall sleeve Damage to exterior wall and masonry and the building structure Attach the wall sleeve with a slope of 1 to 2 to the exterior wall Attach the wall s...

Страница 24: ...oam NOTICE Connect Undercover inner cov ers Leave a 30 mm gap behind the interior wall edge of the wall sleeve otherwise the housing can no longer be inserted Depending on the inner cover to be used c...

Страница 25: ...ather protection grille before installing the external terminal Attach end stop tape on the exterior wall side in the top half of the wall sleeve Before installation carry out a biocidal pre treatment...

Страница 26: ...aws NOTICE Damage to masonry exterior wall caused by incorrectly aligned condensate drip The condensate drip must point towards the floor Align the fixing screws with a spirit level Screw the weather...

Страница 27: ...rnal terminal is fitted Remove the styrofoam disc from the wall sleeve Insert the thermal accumulator from the interior into the wall sleeve The handle points towards the interior The connecting cable...

Страница 28: ...ripping tool screwdriver blade wire end ferrules 3 x 0 75 mm Requirements The reversible fan is inserted into the wall sleeve Shorten the controller connecting cable 3 wire to your determined wall thi...

Страница 29: ...right pole Supply air mode Brown cable V in the left pole Green cable IV in the middle pole White cable III in the right pole Reconnect the connected plug in connector to the plug in connector on the...

Страница 30: ...OUT IV Operating voltage Green CCW Black DIR2 V Signal direction 2 Brown DIR1 III Signal direction 1 White The reversible fan is connected to the controller 4 8 Check function and complete fan install...

Страница 31: ...using a spirit level TIP If the inner cover does not sit firmly enough in the wall sleeve it can optionally be screwed onto the interior wall To do this use the 4 corner drill holes in the inner cover...

Страница 32: ...e 2 m dB A 14 36 Standard sound level difference dB 34 47 Thermal efficiency of heat recovery w 0 84 Input voltage V DC 6 16 Power consumption W 1 3 Specific fan power input W m h 0 2 Protection class...

Страница 33: ...lation 1254 2014 On the energy label you will find the following information from the product data sheet Energy efficiency class SEC class Sound power level Lwa Maximum air flow supply air Demand cont...

Страница 34: ...mperature change t 84 h Maximum air flow rate m h 42 i Electrical input power incl control W 6 j Sound power level Lwa dB A 44 k Reference air flow m h 29 4 l Reference pressure difference Pa 0 m SEL...

Страница 35: ...air flow rate m h 42 i Electrical input power incl control W 6 j Sound power level Lwa dB A 44 k Reference air flow m h 29 4 l Reference pressure difference Pa 0 m SEL W m h 0 18 n Control factor 1 o...

Страница 36: ...mination Light weather protection grille incl sealing tapes Light weather protection grille white RAL 9010 1508 0110 Wall sleeve with styrofoam discs and mounting wedges Wall sleeve R D160x495 1506 00...

Страница 37: ...in supply air mode The rotational speed of the fan is too low Increase the output level Noises Foreign body in the fan Remove foreign body from the fan Clean the ventilation device Thermal accumulato...

Страница 38: ...t the warranty is available at www inventer eu guarantee 9 Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immediately...

Страница 39: ...39 WARRANTY AND GUARANTEE 39 iV Light ventilation device Installation instructions NOTES...

Страница 40: ...Item number 5001 0042 Version 2 0 06 2022 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstra e 4a D 07751 L bersch tz Germany www inventer eu...

Отзывы: