● Please select the wall with certain bearing capacity.
● When doing the installation, vertical slope cannot /-15°.Make sure no lateral
tilt. Otherwise it will affect the function of the heat sink. Cause the output power lower
than expected.
● If install more than one inverter, must leave at least 500mm gap between each inverter.
And each inverter must be at least 500mm above and below. And must install the inverter
at the place where children cannot touch. Please see pic 4.3.
● Consider whether the installation environment is helpful to see the inverter LCD
display and indicator status clearly.
● Must offer a ventilate environment if inverter is installed in the airtight house.
Safety Hints:
Do not place or store any items next to the inverter.
Pic4.3 Installation Gap
Pic4.4 Inverter Installation
The inverter is designed according to the wall mounted type installation, please use the
wall mounted (the brick wall of the expansion bolt) when installing.
4.2 Inverter Installation
Pic4.2 Installation Angle
Anchoring
Mounting bracket
M4*14 Stainless steel screws
Inverter
≤
15
°
≥
500mm
≥
500mm