background image

User manual

Input reading module

NANO IN

Soft >= 1.0

INVEO s.c.

ul. Rzemieślnicza 21

43-340 Kozy

tel: +48 33 444 65 87

www.inveo.com.pl

[email protected]

Содержание NANO IN

Страница 1: ...User manual Input reading module NANO IN Soft 1 0 INVEO s c ul Rzemie lnicza 21 43 340 Kozy tel 48 33 444 65 87 www inveo com pl info inveo com pl...

Страница 2: ...taking into account the basic principles of safety and maintenance Please also keep the user guide that you can use it during subsequent use Manufacturer Liability The manufacturer is not liable for...

Страница 3: ...ONS 8 6 MODULE CONFIGURATION 9 6 1 CHANGING THE PC SETTING FOR MODULE CONFIGURATION 9 6 2 CONFIGURATION OF THE MODULE MODULE THROUGH WEB BROWSER 10 6 3 INPUT READOUT 11 6 4 ACCESS CONFIGURATION 12 6 5...

Страница 4: ...s and important information Failure to follow warnings could cause injury or damage to the module Important information and guidelines Following this guidelines makes the use of the module easier Atte...

Страница 5: ...h the contract of guarantee if the following conditions are met All repairs alterations extensions and device calibrations are performed by the manufacturer or authorized service supply network instal...

Страница 6: ...eric pressure 700 1060hPa Environmental conditions for use Temperature 10 C to 30 C Relative humidity 30 to 75 Atmospheric pressure 700 to 1060hPa Recommended conditions for transportation Temperature...

Страница 7: ...er MODBUS TCP protocol SNMP protocol HTTP protocol User application communication protocol available for user NANO module is equipped with two LEDs indication power and input status 5 2 Technical spec...

Страница 8: ...inary opto isolated inputs connections Typical binary input connection is shown below When placing order customer can choose option with pre polarised traspotor diode or without pre polarisation The o...

Страница 9: ...Start Control Panel Network connections Then right click on the current network connection and click Properties The configuration screen as shown below should be visible on the screen Choose the Inte...

Страница 10: ...admin00 There are several fields used to configure the module network settings MAC Address MAC address of the module Host Name NETBIOS host name of the module Enable DHCP When this box is ticked the...

Страница 11: ...Port Network port of the server that the module can connect to After changing the configuration press the Save Config button 6 3 Input readout Visualisation of input state is shown below Input State i...

Страница 12: ...to New Password field and into Re type Password field then press Save Config to save new passwords Enabling disabling particular service This function enables disables different services By enabling t...

Страница 13: ...otloader enables disables 10 second bootloader mode after module reboot 6 5 SNMP configuration The module is equipped with an SNMP v2c server To enable this feature go to Administration tab Enable SNM...

Страница 14: ...0625 Set counter readcounter Read counter verb Enabled display of additional info stat Displays current state of inputs outputs Examples Read input state module address 192 168 111 15 listening on por...

Страница 15: ...ule IP address p PORT Module Port number w 0 4228250625 Set counter r Read counter l Enabled display of additional info Examples Read input state module address 192 168 111 15 listening on port 9761 t...

Страница 16: ...ingle Register 0x0F Write Multiple Coils 0x10 Write Multiple Registers The registers description is shown in tables 2 and 3 MODBUS TCP Holding Registers Register Name Mode R read W write Description 4...

Страница 17: ...nter1 temp1 0 0 temp1 response Section Description prod_name PE 0 1 prod_name Type of module In this case NANO IN out 00000000 out Output state enabled disabled N A in NANO IN on 00000000 on Output st...

Страница 18: ...3 24 31 CRC WWW control 15 99 x 1 status 0x55 off all other on x x x x x x CRC ON or NO Read channels 15 100 x x x x x x x x CRC CH7 CH0 Chx 2 bytes 1 output state 2 coil state Read channel name 15 10...

Страница 19: ...6 Data 7 CRC 15 10 1 100 0 0 0 0 0 0 132 6 11 Communication with module from outside network If the module is in the LAN network different than PC that connects to it the redirection of ports is nece...

Страница 20: ...button 8 Restoring factory defaults In order to restore the module to its factory defaults press and hold reset button for at least 10 15 seconds The green LED will start flashing 4 times second With...

Страница 21: ...for duration of programming To perform the programming operation go to the Windows command line Start Run type cmd and confirm with Enter Then navigate to the directory where the file resides and ent...

Страница 22: ...Notes...

Страница 23: ...AC110 61F GPN V50 AC110 70177 1011 F03 03 HAS B F03 03 HAS C F03 31 81513201 81513535 81550401 FT1A C12RA W 88981106 H2CAC24A R88A CAGA005S R88A CRGB003CR E R88ARR080100S R88A TK01K DCN1 1 DTB4896VRE...

Отзывы: