![inveo IND2 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/inveo/ind2/ind2_user-manual_2085036019.webp)
7.3
I/O settings
The reader is equipped with two relay outputs and two digital potential-free inputs. The
user can configure the relay trigger mode from the page
I/O Settings
.
Description:
•
out mode –
action on relay triggers:
◦
none –
software shutdown of relay control,
◦
off –
relay deactivation,
◦
on –
relay activation,
◦
toggle –
relay state change to the opposite,
◦
on period –
switching on the relay for the time defined in the field
out time
,
◦
on long period –
switching on the relay for the time defined in the field
out
time long
.
•
out time –
relay activation time for mode
on period
,
•
out time long –
relay activation time for mode
on long period
,
•
out invert –
software override of default relay state – NO by default, invert=NC.
Analogous settings are both available for output #1 and #2.
The input settings configuration table can be found on the same configuration page.
Description:
•
input invert –
programmatically changing the default state of an input,
•
input action
–
the action when the input is switched on:
◦
no action –
no action,
◦
out 1
–
activation of relay output No. 1,
◦
out 2 –
activation of relay output No. 2.
User manual RFID IND2
Page
19
of
61
[B01]