technical specifications
9
The appliance has an unpleasant
smell during use
• The air filter is dirty/blocked
• Clean the air filter as prescribed
The appliance does not switch on for
a period of 3 minutes after it has been
switched on.
• The internal safety system of the
compressor prevents the appliance
from being switched on until
3 minutes have passed since
it was switched off.
• This delay is normal and the
appliance will function normally
after the 3 minutes have passed
Display code
• Low temperature - freeze protection • The appliance is provided with
a freeze protection to prevent
the formation of excess ice.
The appliance automatically restarts
once the thawing process has been
completed.
• Probe error - sensor defective
• If this code is shown on the display,
please contact customer service.
• Full water reservoir
• Empty the internal water reservoir.
In accordance with instructions
in section 6 -
discharging
condensation water
46
•
English
Type number
AC907W
Voltage
220-240Volt ~50Hz
Connected load
1100 Watt
Cooling capacity*
9000 Btu/h (2.81 kW)
EE Class*
A+
EER*
3,1
Power consumption kW
0,9
Power consumption Standby W
0,5
Current consumption nom. A
5,5
Air displacement max. m
3
/h
350
Dehumidification max. ** L/24h
30
Suitable for m
3
80
Refrigerant / GWP type/gr
R-290/3/260 g.
Thermostat range °C
18 - 32
Fan speeds
3
Max. noise level dB(A)
58 dB
Dimensions (hxwxd)
745 x 450 x 396 mm
Nett weight
34 kg
Protection class
IPX0
Remote control
ja
Содержание AC907W