Page12
2
Avoid
button:
1. In any mode of boot, press the button to turn on the function
.
2. Press “ ” , “ ”, “ ” close this function
.
3
Power
button: Operation starts when this button is pressed and stops when you press the
button again.
4
Fan
button: This button is used to select the desired fan speed. Each time you push the
button, the fan speed is shifted in the following sequence:
5
Swing
button:
6
button
LOW MED HIGH AUTO
Fan speed display:
Select LOW fan speed and zones 1~2 will illuminate.
Select MED fan speed and zones 1~4 will illuminate.
Select HIGH fan speed and zones 1~6 will illuminate.
Select AUTO fan speed and zones 1~7 and “AU” will illuminate .
Note: When using the remote control to choose strong wind, wind speed 1~7 will illuminate.
1. This button is used to set the horizontal and vertical airflow.
2.Each time the airflow direction button is pressed, the settings change as follows: Set
vertical airflow
→
Cancel vertical airflow
→
Set horizontal airflow
→
Cancel horizontal airflow
→
Set simultaneous vertical and horizontal airflow
→
Cancel simultaneous vertical and
horizontal airflow
→
Set horizontal airflow.
WARNING:
Manually moving the horizontal and vertical airflow direction louvers could damage
the air conditioner.
1.Under the Test Running mode, press " " " " to be able to check view indoor, outdoor, fault code
.
In other states,press the " "and" " to adjust the temperature within a range of 17°C~30°C
,
To cut to 17 °C again when press downward adjustments set temperature no longer change;
To rise to press adjusted upward again when 30 °C set temperature no longer change.
When setting the temperature, the key cannot adjust the temperature quickly, it can only be
achieved by pressing up and down.
3.
When a failure occurs, E0, E1, E3, E4, E5, Eb, EC, E10, F1, F2, F5, P10, P11, P12, P15, P13, P14, P9.
(for Fixed-speed Type only)
2.
1 2 4 6 7
Page 13
LOCK FEATURE:
The lock feature is activated by pressing down and holding the fan speed and
swing buttons simultaneously for a period of one second.
NOTE:
This feature is available both when the unit is turned on or off. The first time these buttons are
pressed, the unit locks and all other buttons on the unit are disabled (apart from the unlock button).
Please note that the remote control can still be used when the unit is locked. Press the button of the
panel and the lock icon will blink for 5 seconds at 1HZ/SWhen these buttons are pressed again the
unit is unlocked.
Trial operation conditions showed that temperature of T1, if the temperature is less than -15ºC
or - 19ºC, display temperature of -15ºC or - 19ºC.
Trial operation conditions showed that T4 temperature, if the temperature is less than - 19ºC,
show the temperature for - 19ºC.
Trial operation condition, T1, T4 showed highest temperature is 50ºC or 70ºC.
Under test mode, sensor fault can be detected.
The mode key, the wind speed key and the auxiliary function key are not valid, and all other keys are
valid (including the key). Press up and down to select the display room (T1), outdoor (outdoor
temperature), and protection code, and show "nA" when there is no failure or protection.
Commissioning function:
Press " “ and ” " for one second to open the test run, the key is
valid in any mode when it is turned on. On the first time, press this button to enter the test run
state.Run the test run for 30 minutes, press this button again, turn off, and exit the test run condition.