8
Tools for installation
Selection of installation location
1 Level meter
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
14 Measuring tape
Note:
● Please contact the local agent for installation.
Basic requirement
Outdoor unit
will not a
ffect neighborhood.
2.
The location should be well ventilated and dr
y, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3.
The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
Installing the unit in the following pla-ces maycause malfunction. If it is un-
avoidable, please consult the localdealer:
1.The place with strong heat sources,vapors,flammable or explosive gas,or
volatile objects spread in the ai
r
.
2.The place with high-frequency devices (such as welding machine, medical
equipment).
3.The place near coast area.
4.The place with oil or fumes in the ai
r
.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.Do not use the unit in the immediate surroundings of a laundry a bath a
shower or a swimming pool.