HEAT PUMP WATER HEATER MAINTENANCE
43
3
ˊ
Mount a new water pump.
Connect water pump and ensure
it is sealed.
Connect power cord of water
pump.
Mount electric box and electric
box cover.
Mount back side panel and top
cover.
Connect water pipe.
5.
Exploded Views
DHW-C3.5/A1-K
ǃ
DHW-C5.0/A1-K
Exploded views:
3DUWV/LVW
No.
Name of part
Part code
Quantity
1 panel
grill
1
2 panel
ķ
1
ĸ
3
Axial Flow Fan
1
4 fan
motor
1
5 motor
support
ķ
1
ĸ
6 front
baffle
3
1
7
lower panel Sub-Assy
1
8 condenser
ķ
1
01139406
ĸ
9
support rack
1
Содержание DHW-C3.5/A1-K
Страница 1: ......
Страница 3: ...1 PRODUCT...
Страница 4: ......
Страница 12: ...10 CONTROL...
Страница 13: ...HEAT PUMP WATER HEATER CONTROL 11 UNITS CONTROL 1 OPERATION FLOWCHART...
Страница 21: ...19 INSTALLATION...
Страница 23: ......
Страница 30: ...28 MAINTENANCE...
Страница 33: ...HEAT PUMP WATER HEATER MAINTENANCE 31 Low pressure protection flow chart of trouble shooting E3...
Страница 34: ...HEAT PUMP WATER HEATER MAINTENANCE 32 Discharge protection flow chart of trouble shooting E4...
Страница 37: ...HEAT PUMP WATER HEATER MAINTENANCE 35 2 Model DHW C7 2 A1 K 3 Model DHW C3 8 NbA K...