Such a place where is permitting easy connection with
the outdoor unit.
Such a place where is 1m or more away from other electric
appliances such as television, audio device, etc.
Avoid a location where there is heat source, high humidity
or inflammable gas.
Do not use the unit in the immediate surroundings of a
laundry, a bath, a shower or a swimming pool.
Be sure that the installation conforms to the installation
dimension diagram.
The space around the unit is adequate for ventilation (Refer
to Fig.
23
)
Remove the side panel fixing screw and pull to
the front direction (arrow direction) to remove.
(Refer to Fig.
24
)
Loosen two hanger bracket setting bolts (M8)
on eath side for less than 10mm. Remove two
hanger bracket fixing bolts (M6) on the rear side.
Detach the hanger bracker by pulling
it
backward
(Refer to Fig.
26
)
Such a place where
cool air can be distributed throug-
hout the room.
Such a place where is
condersation water is easily drained
out.
Such a place that can handle the weight of indoor unit.
Such a place which has easy access for maintenance.
SELECTION OF INSTALLATION LOCATION.
THERE ARE 2 STYLES OF INSTALLATION.
CEILING TYPE
FLOOR TYPE
Each type is similar to the other as follows;
Determine the mounting position on ceiling or wall
by using paper pattern to indicate indoor frarne.
Mark the pattern and pull out the paper pattern.
Remove the return grill,the side panel and the hanger
bracket from the indoor unit as per procedure bellow.
Press the fixing knob of the relurn grilles, the grilles
will be opened wider and then pull it out from
the indoor.
CAUTION FOR INSTALLATION WHERE
AIR CONDITIONER TROUBLE IS LIKELY
TO OCCUR.
Where there is too much of oil.
Where it is acid base area.
Where there is irregular electrical supply.
Indoor Unit Instrallation
O
PER
INSTALLATION INSTRUCTIONS
)LJ
)LJ
6LGHSDQHOIL[LQJVFUHZ0
)LJ
INSTALLATION
PAPER PLANK
100cm
or more
30cm
or more
60cm
or more
60cm
or more
150cm
or more
3
4
Содержание IKI-09
Страница 1: ...66129903851 IKI 09 IKI 12 IKI 18 IKI 24 IKI 36 IKI 45 IKI 50 Floorceiling Unit...
Страница 2: ......
Страница 4: ......
Страница 35: ...PRECAUTIONS OPERATION INSTRUCTIONS22...
Страница 40: ...Outdoor Unit Installation CAUTION INSTALLATION INSTRUCTIONS Fig 31 Fig 32...
Страница 48: ...PIPE PREPARATION OPERATION INSTRUCTIONS...
Страница 50: ...AIR PURGING AND CHECK OF PIPE LEAKAGE OPERATION INSTRUCTIONS...
Страница 51: ...LIQUID PIPE AND DRAIN PIPE OPERATION INSTRUCTIONS...
Страница 52: ...DRAIN PIPING WORK OPERATION INSTRUCTIONS45...
Страница 55: ......