K800G4 BMC Specification
10
8.
Serial Interface
8.1
Serial Over LAN (SOL)
Serial over LAN provides a mechanism that enables the serial controller of a managed system to be redirected over an IPMI
session over IP. This enables remote console applications to provide access to text-based interfaces for BIOS, utilities,
operating systems, and applications while simultaneously providing access to IPMI platform management functions. SOL is
implemented as a payload type under the new payload capability in RMCP+. This can be used to enable asynchronous
serial-based OS and pre-OS communication over a connection to the BMC.
8.2
SOL Information
Item
Description
Channel#
0x01
Baud Rate
9600
、
19200
、
38400
、
57600
、
115200(default) BPS
Flow control
Hardware flow control
Payload port
623
8.3
SOL Configuration
LAN parameter
Value
Notes
SOL Enable
Disabled
Disable SOL payload type
SOL Authentications
Administrator
Administrator access over SOL
Non-Volatile Bit Rate
115200
115200 baud rate.
Volatile Bit Rate
115200
115200 baud rate.
Gratuitous ARP Interval
4 seconds
ARP responses
Enabled
Access Mode
Enabled
Access Privilege Limit
Enabled
Enabled Authentications
Administrator[Password]
All other Authentications disabled.
SOL Payload Access
Enabled
Enable SOL payload access.
8.4
The Behavior of SOL
The BMC is able to connect and switch UART port between COM Port 1 and SOL. If the SOL connection is abnormal, the
watchdog of BMC would reset itself and return configuration (routing) to the default settings.
Содержание P47 series
Страница 1: ...P N 2017 MNU 000016 June 2018 Revision A 2U Server System Service Manual P47 ...
Страница 3: ......
Страница 64: ...Backplane Connectors OCP Card Connectors Chapter 3 Connectors ...
Страница 65: ...Connectors 2017 MNU 000016 3 1 3 Connectors 3 1 Backplane Connectors Figure 3 1 8x2 5 HDDs Backplane ...
Страница 67: ...Chapter 4 Cable Routing ...
Страница 68: ...Cable Routing 2017 MNU 000016 4 1 4 Cable Routing ...
Страница 69: ...China RoHS Regulations Taiwan BSMI Electromagnetic Emissions Notices Appendix 1 ...
Страница 71: ...Appendix 2017 MNU 000010 II Taiwan BSMI Figure II Taiwan BSMI ...
Страница 75: ...Appendix 2 BIOS SPEC ...
Страница 76: ...BIOS Setup User Manual K800QG4 rev 0 01 Mar 2018 ...
Страница 100: ...Appendix 3 BMC SPEC ...
Страница 101: ...K800G4 BMC Specification 1 K800G4 BMC Specification June 22th 2018 ...