34
Document Number
DCV-00206
Date Released
Dec. 2016
Revision Number/Security level
R00 S2
Retrofit G7+InvencoLink Wayne Ovation (US) Installation Guide
Viewed from inside the pump door.
Left style requires the bracket from the RFK parts. Right style accepts the RFK Panel as is.
19. If you have the Left Style:
a. Start two MS0148
M3x10
screws in the left bushes and tighten them with a Philips-head
screwdriver.
b. Place the MP0590 bracket over the right -hand area (see below for orientation of the
bracket), then start three MS0148
M3x10
screws in the right bushes and tighten them
with a Philips-head screwdriver.
c. Proceed to step 21.
20. If you have the Right Style:
a. Start six MS0148
M3x10
screws in the bushes and tighten them with a Philips-head
screwdriver.