41
Document Number
DCV-00214
Date Released
Mar. 2017
Revision Number/Security level
R00 S2
Retrofit G6+InvencoLink GVR Encore 500S (US) Installation Guide
28. Place an MF0046 cable clip beneath the rib on the RFK Hatch Panel as shown:
29. Further gather the cables and secure them to the cable clip using a cable-tie, taking care to form
a U-shape as shown:
30. Draw any excess cable length back towards the pump door hinge, and re-secure them with the
cable clip (shown in the photo in Step 24) located there.
31. Install the MZ0116 Isolating Cover over the rear of the G6 OPT, onto the RFK Hatch Door.
a. Place the cover with the ground tab to the left over the G6 OPT, ensuring that no cables
are snagged.
b. MZ0116 has captive screws for attachment. Insert and tighten the eight captive screws
into the Stand-Offs on the RFK Hatch Door:
Use cable-tie thru feature
on back of G6 OPT
Place cable
clip here
U-shape form allows cables to
flex when Hatch Door is opened.
However, ensure cables do not
come below this line