Invacare NordBed Essential Скачать руководство пользователя страница 10

Invacare® NordBed™ Essential

3.

4.

5.

1.

Place the mounting brackets of the backup battery
over the square tube at the foot end of the base
frame.

2.

Fix the backup battery by tightening the two finger
screws.

3.

On the control unit turn the lock 90 degrees
counter-clockwise to open the lid and remove it.

4.

Connect the cable from the backup battery to the
control unit in the socket labeled with the battery
symbol.

5.

Put the lid back on the control unit and close it by
turning the lock 90 degrees clockwise.

Charging the batteries

WARNING!
Risk of explosion

Old or faulty batteries may generate an
explosive gas mixture during charging.

– The battery box is provided with vents to

ensure adequate ventilation of the box. Do
not block or cover the vents, as this may
result in pressure built-up and the risk of
explosion.

1.

Connect the control unit to the mains.

The control unit must be connected to the
mains for 24 hours prior to first use.

Batteries must be charged, at least, every 6
months for maintenance purposes.

Preventive maintenance

Frequent, sudden discharges reduce the lifetime
of the battery.

We recommend the batteries to be tested at least once
a year.

Batteries are not damaged by continuous connection to
the mains.

Exchanging the batteries

WARNING!
Environmental Hazard

Disposal of batteries.
This product may contain substances that could
be harmful to the environment if disposed of
in places (landfills) that are not appropriate
according to legislation.

– DO NOT dispose of batteries in normal

household waste.

– Batteries MUST be taken to a proper disposal

site. The return is required by law and free
of charge.

– Do only dispose discharged batteries.
– Cover terminals of lithium batteries prior to

disposal.

– For information on the battery type see

battery label or technical data.

Batteries have to be exchanged after 4 years.
Depending on how the back up is used the exchange
may have to take place earlier.

Batteries must be exchanged as sets.

Batteries must be replaced with batteries of the
same type or mechanically and electrically compatible
batteries. See technical data.

Batteries, in a set, must have identical production
codes.

Prior to insertion make sure that the battery set is
correctly connected according to the drawing (in
the battery box), and that none of the connections
are loose.

Technical data

Battery type: Lead-acid

Capacity: 1.2 Ah

Input voltage: 29–45 V DC

Output voltage: 24 V DC, 1.2 A

10

1657008-A

Содержание NordBed Essential

Страница 1: ...Invacare NordBed Essential en Bed Service Manual PROVIDER Keep this manual The procedures in this manual MUST be performed by a qualified technician...

Страница 2: ...ation duplication or modification in whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare...

Страница 3: ...1 1 Installing side rails 8 4 1 2 Installing the Freya Embla side rail 8 4 1 3 Installing the Ane side rail 8 4 1 4 Installing the Torill side rail 9 4 2 Backup battery 9 5 Servicing 11 5 1 General se...

Страница 4: ...ee the user manual For more information about the product for example product safety notices and product recalls contact your Invacare representative See addresses at the end of this document 1 2 Symb...

Страница 5: ...egional differences refer to your local Invacare catalog or website for available accessories or contact your local Invacare representative See addresses at the end of this document IMPORTANT Some rep...

Страница 6: ...es 2 Align the slots in the bed end with the tabs on the Sanne bracket and place the bed end onto the tabs 3 Push down firmly and ensure that the bed end is fully seated in the tabs 4 Rotate the locki...

Страница 7: ...cm between the bed end and the mattress bow to avoid entrapment of fingers Always make sure to tighten the screws for the mattress support extension The bed can be extended by 10 cm in the foot end of...

Страница 8: ...into the bed end guideways Make sure that all side rail bars are above the locking pin and properly locked Make sure that the straps between the bars are not damaged or loose Mounting 1 Lift the uppe...

Страница 9: ...ide rails of the same length can be mounted on each side of the bed The installation of the long and the short version of the Torill side rail is similar 1 Raise the side rail to its high position and...

Страница 10: ...the batteries to be tested at least once a year Batteries are not damaged by continuous connection to the mains Exchanging the batteries WARNING Environmental Hazard Disposal of batteries This product...

Страница 11: ...ttress support section actuators running properly q Cables correctly wired and undamaged q Electric plugs undamaged q Cable insulation and actuator housings no cracks or damages q Damaged coating repa...

Страница 12: ...Wipe dry with a soft cloth Metal components Method Wipe off with a wet cloth or soft brush Max temperature 40 C Solvent chemicals Ordinary household cleaning agents and water Drying Wipe dry with a so...

Страница 13: ...Backup battery optional C not in use covered with a blind plug D Height adjustment actuator lower half E Mains power cable F Height adjustment actuator upper half G Tight section actuator H Back sect...

Страница 14: ...nd routed correctly Make sure cables do not touch the floor and cannot block the castors Make sure cables cannot get squeezed by moving parts during operation For the correct routing of the cables bet...

Страница 15: ...agnetic key A in the slot on the side of the hand control 2 Press and hold button B and C for 3 seconds to initiate the system reset and hold the buttons pressed until the following sequence is comple...

Страница 16: ...353 1 810 7085 ireland invacare com www invacare ie United Kingdom Invacare Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ Tel 44 0 1656 776 222 Fax 44 0 1656 776 220 uk invacare com www in...

Отзывы: