background image

SECTION 6—FRONT RIGGINGS

Formula™ Powered Seating

44

Part No 1122170

Raising/Lowering Elevating Legrests and/or Adjusting 

Calfpads

NOTE: For this procedure, refer to 

FIGURE 6.14.

Raising/Lowering Elevating 

Legrests

1. Perform one of the following:

• Raising - Pull back on the release 

lever until the leg is at the desired 

height.

• Lowering - Support leg with one 

hand and push release lever 

downward with other hand.

Adjusting Calfpads

1. Turn the calfpad towards the outside of 

the wheelchair.

2. Slide the calfpad UP or down until the 

desired position is obtained.

FIGURE 6.14   

Raising/Lowering Elevating 

Legrests and/or Adjusting Calfpads

NOTE: If one of the top two calfpad adjustment positions is being used, the legrest will need to be 

raised to avoid interference with the front stabilizers while going over obstacles or going UP and 

down ramps. Refer to Raising/Lowering Elevating Legrests on page 44.

3. Turn the calfpad towards the inside of the wheelchair.

Adjust Calfpad

Secure Calfpad

Legrest to Normal 

Position

All manuals and user guides at all-guides.com

Содержание Formula Powered Seating

Страница 1: ...his product read this manual and save for future reference For more information regarding Invacare products parts and services please visit www invacare com Formula Powered Seating Tilt Recline Elevat...

Страница 2: ...ALERS AND QUALIFIED TECHNICIANS DO NOT SERVICE OR OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING 1 THE OWNER S OPERATOR AND MAINTENANCE MANUAL 2 THE SERVICE MANUAL IF APPLICABLE AND 3...

Страница 3: ...Lock Out 23 Operating Powered Seating Systems 24 MPJ Joystick Switches and Indicators 28 Preparing the Joystick for Use 33 Repositioning the Joystick 34 SECTION 6 FRONT RIGGINGS 35 Installing Removing...

Страница 4: ...2 Using the Proper Batteries 63 Replacing Batteries 63 Cleaning Battery Terminals 66 Removing Installing the Batteries From Into the Wheelchair 66 When to Charge Batteries 70 Charging Batteries 70 SEC...

Страница 5: ...TS has not been crash tested in accordance with WC 19 Use these transport brackets only to secure an unoccupied wheelchair during transport As of this date the Department of Transportation has not app...

Страница 6: ...ly Wheelchairs should be examined during maintenance for signs of corrosion water exposure incontinence etc Electrical components damaged by corrosion should be replaced IMMEDIATELY Wheelchairs that a...

Страница 7: ...base All Wheelchairs Refer to Service Manual to reposition the seat otherwise serious personal injury and damage will result WARNING P N 1114823 Rev B 5 10 06 Weight Capacity Label located here Seria...

Страница 8: ...LABEL LOCATIONS Formula Powered Seating 8 Part No 1122170 Wheelchairs with Elevate Wheelchairs with Ventilator Trays All manuals and user guides at all guides com...

Страница 9: ...EVATE 0 Seat Angle 5 Seat Angle 0 55 3 5 60 3 RECLINE RANGE MEASURED RELATIVE TO THE GROUND RECLINE ONLY TILT RECLINE AND TILT RECLINE ELEVATE 0 Seat Angle 5 Seat Angle 90 170 3 95 170 3 SEAT TO FLOOR...

Страница 10: ...11 16 inches Desk or Full Length LEGRESTS Swingaway Footrests Power or Manual Center Mount Footrests Manual or Power Elevating Legrests HEADRESTS Curved Contoured Small or Large WEIGHT LIMITATION ALL...

Страница 11: ...nt attendants and bystanders are clear of all pinch points before returning the tilted seat to the full upright position or lowering the elevating seat Before adjusting repairing or servicing the whee...

Страница 12: ...r ALWAYS shift your weight in the direction you are turning DO NOT shift your weight in the opposite direction of the turn Shifting your weight in the opposite direction of the turn may cause the insi...

Страница 13: ...reclined back angle position over 20 relative to the vertical position If the drive lock out does not stop the wheelchair from operating or the seat from elevating lowering in a tilt position over 20...

Страница 14: ...id wheelchair as a weight training apparatus Invacare shall not be liable for bodily injury and the warranty is void Weight Limitation Refer to Typical Product Parameters in this manual and the Typica...

Страница 15: ...re common sources of radiated EMI There are a number of sources of relatively intense electromagnetic fields in the everyday environment Some of these sources are obvious and easy to avoid Others are...

Страница 16: ...EMENT WHICH COULD RESULT IN SERIOUS INJURY 1 Do not operate hand held transceivers transmitters receivers such as citizens band CB radios or turn ON personal communication devices such as cellular pho...

Страница 17: ...g tube when the seat is in the lowest seat to floor height Pinch point may occur when returning the tilted seat to the full upright position or lowering the elevated seat Make sure the hands and body...

Страница 18: ...heelchair base Safety Inspection Checklists Inspect Adjust Initially CAUTION As with any vehicle the wheels and tires should be checked periodically for cracks and wear and should be replaced Inspect...

Страница 19: ...ting system Inspect Adjust Monthly Clean upholstery and armrests Clean dirt and lint from axles Clean dirt and lint from bearings Inspect seat positioning strap for any signs of wear Ensure buckle lat...

Страница 20: ...elchair base owner s manual and the individual Electronics Manual supplied with each wheelchair SYMPTOM PROBABLE CAUSE SOLUTIONS Wheelchair Power On but does not drive System tilted or reclined beyond...

Страница 21: ...odule is not communicating with the control module Error code E200 Check the connections between the joystick or display and the controller Turn the power off and then back on Replace the controller i...

Страница 22: ...e system is tilted or reclined beyond drive lock out angle of 20 Error code W01 Return the system to upright position MAX BACK ANGLE displays The wheelchair back has reached the maximum programmed bac...

Страница 23: ...chair delivery and after adjusting the back angle drive lock out switch tilt system or recline system tilt and recline the seat back to the farthest driving position immediately before drive lock out...

Страница 24: ...ing system while the wheelchair is moving DO NOT operate the tilt or elevate function near or under a fixed object such as a table or desk The elevating seat option is equipped with a speed reduction...

Страница 25: ...the tilt function Refer to the electronics manual for complete switch option operating instructions 3 Release four way switch to neutral position SEATING SYSTEM FOUR WAY SWITCH FORWARD REAR LEFT RIGHT...

Страница 26: ...joystick direction or quadrant Detail B for activation of that operation 4 Select the desired operation using the joystick or an equivalent switch NOTE While operating the powered seating system the i...

Страница 27: ...Tilt Down Icon Move the joystick right to use this function DETAIL B ACTUATOR CONTROL SWITCH MODE EXAMPLE SCREEN DETAIL C EXAMPLE SCREEN DURING POWERED SEATING OPERATION Text Icon Mode Icons Actuator...

Страница 28: ...2 can be programmed for slower speeds and less responsiveness or vise versa The other two drive programs could be indoor and outdoor versions of DRIVE 1 and DRIVE 2 Selecting the Drive Mode 1 Move th...

Страница 29: ...rmation on the status of the wheelchair through a backlit display The LCD display is readable in both bright sunlight and complete darkness Splash Screen NOTE For this procedure refer to FIGURE 5 4 Th...

Страница 30: ...g exclamation point inside a triangle indicator when the chair has a condition that requires attention The status indicator will show a STOP sign when a serious condition exists The chair will not be...

Страница 31: ...screen FIGURE 5 6 LCD Display Screens Driving Screen Connected Devices Screen NOTE For this procedure refer to FIGURE 5 7 This screen is displayed if the Mode Select switch is held active for about 10...

Страница 32: ...tch is used to stop the wheelchair Remote Mode Reset Switch The remote mode reset switch functions the same way as the mode switch Refer to Mode Switch on page 33 Remote On Off Switch The remote On Of...

Страница 33: ...e LCD will display PRESS RESET NOTE In these modes Standby Select allows the reset switch to be bypassed for users unable to activate the switch Memory Card Slot The memory card slot is used with the...

Страница 34: ...ing the threaded plate of the mounting bracket is on the inside of the arm tube as shown in FIGURE 5 9 FIGURE 5 9 Repositioning the Joystick 5 Using the three hex mounting screws and washers secure bo...

Страница 35: ...injury While the wheelchair is moving minimum ground clearance for the front rigging is three inches If the wheelchair is not moving the front rigging MUST maintain a minimum of one inch ground clear...

Страница 36: ...stment on page 36 Footrest Height Adjustment WARNING Minimum ground clearance for the footrest is 3 inches otherwise personal injury or damage may result PHAL4A Front Riggings NOTE For this procedure...

Страница 37: ...to the wheelchair Refer to Installing Removing Footrests on page 35 8 Reinstall any accessory onto the footrest s FIGURE 6 4 Footrest Height Adjustment 70 and PW93 70 Taper NOTE For this procedure ref...

Страница 38: ...ting Front Riggings Adjusting Replacing Telescoping Front Rigging Support WARNING If the telescoping tubes need to be extended greater than two inches then the seat must be repositioned rearward to en...

Страница 39: ...70 39 Formula Powered Seating FIGURE 6 7 Adjusting Replacing Telescoping Front Rigging Support Telescoping Front Tube Cap Screws Spacers Threaded Blocks Cap Screws Spacers Side Rail Side Rail All manu...

Страница 40: ...ily NOTE If footplate s motion is too tight loosen the mounting screw and locknut approximately turn counterclockwise NOTE If the footplate s motion is too loose tighten mounting screw and locknut app...

Страница 41: ...her and locknuts that secure the footplate to the footplate hinge FIGURE 6 9 2 Position the footplate to the necessary angle to accommodate the user FIGURE 6 10 3 Retighten the two flat screws washers...

Страница 42: ...oop to the footrest 4 Slide heel strap over cane of footrest assembly Articulating 1 Remove the two mounting screws that secure the heel loop to the articulating footplate Assembly 1 Replace heel stra...

Страница 43: ...4 Repeat STEPS 1 3 for the opposite legrest 5 After the user is seated in wheelchair adjust footplate to correct height by loosening nut and sliding the lower footrest assembly UP or down until desir...

Страница 44: ...Turn the calfpad towards the outside of the wheelchair 2 Slide the calfpad UP or down until the desired position is obtained FIGURE 6 14 Raising Lowering Elevating Legrests and or Adjusting Calfpads...

Страница 45: ...ith the other while simultaneously pulling the center mount footrest out of the mounting bracket of the seat frame Installing Power Center Mount Footrests 1 Position the link drive tube between the mo...

Страница 46: ...se Lever Rigging Pivot Pin Center Mount Footrest Seat Frame Mounting Bracket Manual Center Mount Footrest Power Center Mount Footrest DETAIL A DETAIL B DETAIL C Short Quick Release Pin Link Plate Cent...

Страница 47: ...ounting screws that secure the footrest extension tube to the extension tube housing 2 Adjust the footrest extension tube to the desired height and align the corresponding holes to the mounting holes...

Страница 48: ...6 16 for the location of the release lever 2 Disengage the release lever not shown to lock the center mount footrest in the new position FIGURE 6 17 Adjusting the Angle of the Manual Center Mount Foot...

Страница 49: ...e refer to FIGURE 6 20 NOTE This procedure applies to both power and manual center mount footrests NOTE The tension can be adjusted to increase or decrease the rotation effort of the flip up footplate...

Страница 50: ...to the carriage assembly 2 Move the calf pad mounting bracket to the desired position 3 Install the two depth adjustment screws to secure the calf pad mounting bracket to the carriage assembly 4 Check...

Страница 51: ...ry may occur CAUTION Never allow items to become trapped between the legrest assemblies otherwise damage to the power legrests may occur Ensure that all parts of both power legrests are clear of any o...

Страница 52: ...mper cable 2 Push legrest release handle and swing legrest to the outside of the wheelchair 3 Lift up on powered legrest and remove from wheelchair 4 Repeat STEPS 1 3 for opposite power legrest FIGURE...

Страница 53: ...p back armrest into the arm sockets on the seat frame 3 Install the quick release pin through the rear arm socket and flip back armrest 4 Lock the flip back armrest by pressing the flip back armrest r...

Страница 54: ...te flip back armrest if necessary FIGURE 7 2 Adjusting Flip Back Armrests Positioning Flip Back Armrests for Use 1 Make sure the flip back armrest release lever is in the up horizontal position 2 Inst...

Страница 55: ...e the armrest from the seat frame Installing Armrests 1 Position the armrest on the seat frame as shown in FIGURE 7 3 2 Press the release button at the rear of the armrest in 3 While holding the relea...

Страница 56: ...locknut securing the arm adapter plate to the back cane Detail C 4 Adjust the armrest to the desired height for the user NOTE The armrests can be at different heights to accommodate the user NOTE The...

Страница 57: ...ket Bolt Height Adjustment Holes Locknut DETAIL B FORMULA TRE SEATING SYSTEM WITH CONVENTIONAL BACK DETAIL C FORMULA TRE SEATING SYSTEM WITH CONTOURA BACK DETAIL A FRONT OF ARMREST Locknut Cap Screws...

Страница 58: ...the Back Angle NOTE For this procedure refer to FIGURE 8 1 1 Loosen but DO NOT remove the two lower hex screws securing the cane brackets to the back canes 2 Remove the two upper hex screws washers an...

Страница 59: ...ame 4 Remove the two halves of the seat positioning strap from the rear seat frame 5 Reposition the two new seat positioning strap inside of the seat frame as shown 6 Reinstall the two mounting screws...

Страница 60: ...NOT remove the thumb screw that secures the headrest to the headrest mounting bracket 2 Remove the headrest from the headrest mounting bracket Installing 1 Make sure thumb screw is loose 2 Install th...

Страница 61: ...or towards the rear of the wheelchair 3 If necessary reposition the headrest to the desired position headrest will move in any direction 4 While holding the headrest in the desired position securely...

Страница 62: ...most convenient method and assures that the battery acid will not spill It also helps to prolong the life of the battery DO NOT tip the batteries Keep the batteries in an upright position NEVER allow...

Страница 63: ...emoving Installing the Batteries From Into the Wheelchair on page 66 2 Cut the tie wraps that secure the battery terminal covers to the battery terminals 3 Slide the RED battery terminal cover back on...

Страница 64: ...the NEGATIVE battery cable to the NEGATIVE battery post with existing mounting screw and locknut 10 Secure the bracket of the POSITIVE battery cable to the POSITIVE battery post with existing mounting...

Страница 65: ...over Tie Wraps Tie Wraps Bracket of POSITIVE Battery Cable NEGATIVE Battery Cable Bracket of POSITIVE Battery Cable Mounting Screw Mounting Screw Locknut Locknut Locknut Locknut POSITIVE Battery Termi...

Страница 66: ...NOTE Upon completion areas should be shiny not dull 4 Carefully dust off all metal particles Removing Installing the Batteries From Into the Wheelchair Removing the Battery Door and Rear Shrouds CAUT...

Страница 67: ...Battery Door and Rear Shrouds Thumb Screws STEP 2 Disconnect Batteries from the controller here STEP 8 Mounting Screw STEP 5 Batteries with Battery Tray Battery Door STEP 6 Mounting Screw STEP 5 Rear...

Страница 68: ...on page 69 1 Position the battery with the BLACK battery connector tab into the REAR of the battery box as shown 2 Plug the BLACK battery connector tab into the RIGHT battery connector 3 Position the...

Страница 69: ...RE 10 2 on page 67 using the four hex screws and four locknuts if applicable Torque to 75 in lbs 2 Reinstall battery door onto front of wheelchair 3 Install both mounting screws on the side of the bat...

Страница 70: ...nts appear between E and F At this level the user should charge the batteries as soon as possible FIGURE 10 5 When to Charge Batteries Charging Batteries WARNING NEVER attempt to recharge the batterie...

Страница 71: ...G NEVER leave the charger unattended when the breaker has tripped A fault condi tion exists Unplug and discontinue using immediately Contact an Invacare dealer NOTE If performing the charging procedur...

Страница 72: ...ION 10 ELEVATE BATTERIES Formula Powered Seating 72 Part No 1122170 FIGURE 10 6 Charging Batteries MPJ Joystick Charger Programming Port On Front of Joystick All manuals and user guides at all guides...

Страница 73: ...tely 13 inches long 14 inches wide and 14 inches high Use of ventilators larger than the above specifications may result in damage to the ventilator or stability issues Wheelchairs with Recline System...

Страница 74: ...part of the back assembly interferes with the ventilator tray B If necessary contact a qualified technician to adjust the recline down limit to avoid interference with the ventilator tray FIGURE 1 Pre...

Страница 75: ...or replacement For warranty service please contact the dealer from whom you purchased your Invacare product In the event you do not receive satisfactory warranty service please write directly to Inva...

Страница 76: ...te nature of the defect and if the product is serialized indicate the serial number Do not return products to our factory without our prior consent LIMITATIONS AND EXCLUSIONS THE FOREGOING WARRANTY SH...