background image

SPECIAL NOTES

Invacare® Element™

4

Part No 1160840

SPECIAL NOTES

Signal

 

words

 

are

 

used

 

in

 

this

 

manual

 

and

 

apply

 

to

 

hazards

 

or

 

unsafe

 

practices

 

which

 

could

 

result

 

in

 

personal

 

injury

 

or

 

property

 

damage.

 

Refer

 

to

 

the

 

following

 

table

 

for

 

definitions

 

of

 

the

 

signal

 

words.

Receiving Inspection

Remove

 

product

 

from

 

package

 

and

 

inspect

 

for

 

damage.

 

If

 

there

 

is

 

any

 

damage,

 

DO

 

NOT

 

use.

 

Contact

 

your

 

dealer/

 

Home

 

Care

 

equipment

 

provider.

Intended Use

The

 

oxygen

 

conserving

 

regulator

 

is

 

intended

 

for

 

prescription

 

use

 

only,

 

to

 

be

 

used

 

as

 

part

 

of

 

a

 

portable

 

oxygen

 

delivery

 

system

 

for

 

patients

 

that

 

require

 

supplemental

 

oxygen

 

in

 

their

 

home

 

and

 

for

 

ambulatory

 

use.

 

Disposal Instructions

This

 

device

 

and

 

its

 

packaging

 

contain

 

no

 

hazardous

 

materials.

 

No

 

special

 

precautions

 

need

 

to

 

be

 

taken

 

when

 

disposing

 

the

 

device

 

and/or

 

it’s

 

packaging.

SIGNAL 

WORD

MEANING

DANGER

Danger indicates an imminently hazardous situation which, 
if not avoided, will result in death or serious injury.

WARNING

Warning indicates a potentially hazardous situation which, 
if not avoided, could result in death or serious injury.

CAUTION

Caution indicates a potentially hazardous situation which, 
if not avoided, may result in property damage or minor injury 
or both.

Содержание Element IOC100P

Страница 1: ...nd user User Before using this product read this manual and save for future reference For more information regarding Invacare products parts and services please visit www invacare com User Manual Inva...

Страница 2: ...tions or instructions contact a healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may occur ACCESSORIES WARNING Invacare products...

Страница 3: ...6 SECTION 1 GENERAL GUIDELINES 7 Operating Information 7 SECTION 2 FEATURES 10 SECTION 3 INSTALLING THE CONSERVING REGULATOR 12 SECTION 4 OPERATING INSTRUCTIONS 14 SECTION 5 REMOVING THE CONSERVING R...

Страница 4: ...used as part of a portable oxygen delivery system for patients that require supplemental oxygen in their home and for ambulatory use Disposal Instructions This device and its packaging contain no haz...

Страница 5: ...g to the patient It supplies a pulse of oxygen atthebeginningofeachbreath Thisreducestheoxygendemand on the system and limits the drying of the airways The flow is determined by setting the flow contr...

Страница 6: ...and eliminating unnecessary oxygen waste When we breathe approximately one third of the time is spent inhaling and two thirds exhaling As a result oxygen delivered by continuous flow is wasted during...

Страница 7: ...icensed by the law of the state in which he she practices to use or order the use of this device This product is not intended as a life sustaining or life supporting device Only personnel instructed a...

Страница 8: ...xplosive substances vapors or atmosphere ALWAYS follow ANSI and CGA standards for Medical Gas Products and Flowmeters E 7 and Oxygen Handling G 4 NO OXYGEN is delivered when the pointer is aligned wit...

Страница 9: ...r lubricant such as WD 40 or 3 in 1 oil If continued difficulty is experienced contact your supplier for assistance DO NOT store cylinders near sources of heat or flame DO NOT use while sleeping witho...

Страница 10: ...e back page Model IOC100P FIGURE 2 1 Model IOC100P Cylinder Post Valve T Handle Clamp This is used to attach the unit to any CGA870 post valve cylinder Oxygen Pressure Gauge Enables the user to monito...

Страница 11: ...nto the holes on the CGA870 post valve CGA870 Seal Washer Metal Washer with Viton or equivalent Seal Creates the interface between the post valve and the conserver regulator Besides offering a rugged...

Страница 12: ...or to use If the cylinder post valve should come in contact with such substances it should be cleaned off with a damp cloth prior to connecting it to the conserving regulator DO NOT direct flow of oxy...

Страница 13: ...ins toward the holes on the cylinder neck 3 Align the two pins and gasket with the corresponding holes on the cylinder post valve FIGURE 3 1 Attaching the IOC100P to the Cylinder NOTE Cylinder post va...

Страница 14: ...ng when the oxygen conserving regulator is in use This may damage the oxygen conserving regulator 1 Prior to each use inspect product for visible damage DO NOT use if any damage is found WARNING DO NO...

Страница 15: ...ed 7 Position the cylinder so the oxygen cylinder valve outlet is pointing away from the user and any other person s 8 Attach a standard adult single lumen oxygen nasal cannula no longer than seven fe...

Страница 16: ...n continuous flow mode is preset to 2 L min liters per minute Remember that in this mode the oxygen will be consumed at a much faster rate Return to another source before running out of oxygen Refer t...

Страница 17: ...ygen supply cylinder valve and continue breathing through the nasal cannula until no further oxygen flow is detected 13 Remove the nasal cannula and turn the selector switch to the 0 OFF position 14 W...

Страница 18: ...le beyond the stop Otherwise damage to the oxygen conserving regulator will occur NOTE For information on how to operate the cylinder consult your equipment provider 1 Completely close the oxygen cyli...

Страница 19: ...RESSURE 200 psi to 3000 psi 13 8 bar to 206 8 bar REGULATOR Built in 25 5 psi 1 7 bar 34 bar brass high pressure with aluminum low pressure materials DIMENSIONS Weight Approximately 14 8 ounces 420 gr...

Страница 20: ...minute as compared with ten 10 times per minute Refer to OXYGEN DURATION TABLE below OXYGEN DURATION TABLE SHOCK VIBRATION Not to exceed IEC 601 1 requirements Not to exceed IEC 68 2 6 IEC 68 2 34 No...

Страница 21: ...lutions DO NOT immerse product in any kind of liquid All repairs MUST be done by Invacare Corporation 1 Disconnect all connections before cleaning 2 After each use clean exterior of the product with a...

Страница 22: ...Oxygen conserving regulator not sensing breath 5 Oxygen cannula is blocked or kinked 1 Turnthecylindervalveto the ON position 2 Set to prescribed setting 3 Replace cylinder 4 Check position of cannul...

Страница 23: ...ee telephone number identified on the back cover of this manual Upon receiving notice of an alleged defect in a product Invacare will issue a serialized return authorization It shall be the responsibi...

Страница 24: ...INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT BE APPLICABLE THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE...

Отзывы: