38
20.
TROUBLE SHOOTING
* If it is difficult for you to troubleshoot despite the following method, please contact to the seller of
the machine.
20 - 1
If the electricity power of the machine does not turn on,
1)
Check up whether the electricity is well supplied to the electricity outlet
→
If so,
2)
Check up whether the plug inserted rightly into the electricity outlet,
→
If so,
3)
Check up whether the electricity line is cut off
→
If so, exchange it with a new one.
But, if not cut off,
4)
Check up whether the electricity inlet of the machine is all right
→
If not, exchange it
with a new one. But, if all right,
5)
Check up whether N.F.B is ON
→
If N.F.B is off, refer to 20-10. But, if N.F.B is ON,
※
N.F.B (No Fuse Breaker) = MCCB (Mold Case Circuit Breaker)
6)
Check up whether the fuse is cut off
→
If so, exchange it with a new one.
20 - 2
If the machine does not start to operate, after the electricity power of the
machine turns on,
For first, check up and take action according to 1) and 2). Despite that, if the machine does
not start to operate, find out what among 3) ~ 5) answers the actual condition and take action.
1)
Check up whether AIRZERO AZ-( ) appears on LCD screen
→
If not, Check up
whether compressed air is supplied rightly. ( Refer to 8.5 ). But, if so,
2)
Check up whether FOOT S/W is all right ( Refer to the following method )
※
Check up FOOT S/W
Check up whether FOOT among input led on the control box turns on
→
If so, FOOT
S/W is all right. But, if not, FOOT S/W is out of order. Exchange it with a new one.
3)
If the nozzle does not move forward despite stepping on FOOT S/W, at the V or M1~M8
MODE
(1)
Check up whether UP and BACK among input led on the control box turns on
→
if
not, adjust the location of sensor 1 and 4. ( Refer to 21. SENSOR SETTING ). But, if
so,
(2)
Check up whether NOZZLE among output led on the control box turns on
→
If so,
the solenoid valve set is out of order. But, if not, the control box is out of order.
4)
If the upper sealing bar can
’
t do 1
st
going down despite stepping on FOOT S/W, after the
nozzle has moved forward,
(1)
If the upper sealing bar goes down a little and the goes back to up,
Check up whether MIDDLE among input led on the control box turns on momentarily
→
If so, adjust the location of sensor 2 and 2-1. ( Refer to 21. SENSOR SETTING )
But, if not, check up whether compressed air is supplied rightly. ( Refer to 8.5 )
(2)
If the upper sealing bar does not go down at all,
Содержание AIR ZERO AZ
Страница 5: ...5 The caution against a danger of burn by heat around heat wire 1 3 Location of caution label...
Страница 7: ...7...
Страница 11: ...11 7 NAME OF EACH PART 7 1 AZ type...
Страница 27: ...27 17 2 AZV type...
Страница 28: ...28 18 INSIDE DRAWING 18 1 AZ type...
Страница 31: ...31 Please understand there could be changes of parts according to the model and option...
Страница 33: ...33...
Страница 34: ...34 19 2 AZV type...
Страница 35: ...35 19 220 1Ph...
Страница 36: ...36 20 220 3Ph...
Страница 37: ...37 21 380 3Ph...