Intrise AIR ZERO AZ Скачать руководство пользователя страница 1

 

 

USER

S MANUAL 

( AZ-Series NOZZLE TYPE VACUUM SEALER ) 

 

 

 

 

 

 

 

www.airzero.co.kr

 

 

INTRISE CO., LTD. 

27, Haean-ro 213beon-gil, Danwon-gu, Ansan-si, Gyeonggi-do, Korea 

TEL : +82-31-407-9000 / FAX : +82-31-407-9090 

Содержание AIR ZERO AZ

Страница 1: ...1 USER S MANUAL AZ Series NOZZLE TYPE VACUUM SEALER www airzero co kr INTRISE CO LTD 27 Haean ro 213beon gil Danwon gu Ansan si Gyeonggi do Korea TEL 82 31 407 9000 FAX 82 31 407 9090...

Страница 2: ...a good sealing P 9 5 DEFINITION BASIC FUNCTION OF THE MACHINE P 10 5 1 5 2 6 USABLE RANGE OF PACKING ENVELOPE P 10 6 1 6 2 7 NAME OF EACH PART P 11 14 7 1 AZ type 7 2 AZV type 8 INSTALLATION P 15 8 1...

Страница 3: ...16 1 HEAT WIRE 16 2 TEFLON SHEET 16 3 TEFLON TAPE 16 4 UPPER TEFLON TAPE 16 5 SEALING RUBBER 16 6 COMPRESSION SPONGE 17 LAY OUT DRAWING P 27 28 17 1 AZ type 17 2 AZV type 18 INSIDE DRAWING P 29 32 18...

Страница 4: ...the user does not conform to this user s manual INTRISE CO LTD has no legal liability Therefore please keep this user s manual near you whenever you use the machine If you need more information beyon...

Страница 5: ...5 The caution against a danger of burn by heat around heat wire 1 3 Location of caution label...

Страница 6: ...A Is the model same as your order B Are there all things listed from 2 1 to 2 4 C Is there any damage to all things listed from 2 1 to 2 4 2 1 The machine 2 2 Spare Parts 1 Heat Wire 2 Teflon Tape 3 F...

Страница 7: ...7...

Страница 8: ...erature and high humidity Especially the temperature of work place suitable for this machine is 0 50 8 Please do not insert the hand between the sealing bars 1 A long time use of the machine accumulat...

Страница 9: ...damage exchange it with new one Refer to 16 CONSUMABLES CHANGE 4 A long time use of this machine raises the temperature of sealing bar and can change proper sealing condition Please set sealing time m...

Страница 10: ...Vacuum Gas flushing Sealing 6 Vacuum Gas flushing Vacuum Gas flushing Sealing 6 USABLE RANGE OF PACKING ENVELOPE 6 1 This machine s sealing process is as follows 1 Press packing film with sealing bars...

Страница 11: ...11 7 NAME OF EACH PART 7 1 AZ type...

Страница 12: ...front of the packing envelope during the 1st going down of upper sealing bar and to seal the front during the 2nd going down of upper sealing bar 3 CONTROL BOX Refer to 9 FUNCTION USE OF EACH BUTTON...

Страница 13: ...e head between 0 90 by using this 8 CASTER This is used to move the machine 9 NOZZLE FORWARDING DEGREE CONTROL RING With this the degree nozzle moves forward can be controlled So the case user can set...

Страница 14: ...t of the machine In the other hand if the compressed air is less than 4 5 kgf there is a chance that the machine does not operate well Pull up the air regulator and turns right clockwise Then air pres...

Страница 15: ...V Vacuum Degree Kpa of vacuuming The machine is operated by the preset vacuum degree If you select 45 the vacuum works until the vacuum degree for the inside of vacuum bag approaches to 45 Kpa and the...

Страница 16: ...hether AIRZERO AZ appears on LCD screen If other words appear check whether the compressed air is supplied properly Refer to 8 5 11 2 Press VAC TIME button and Select whether to do vacuum procedure by...

Страница 17: ...n arrange the packed object as you like and step on the FOOT S W once more Then the operation proceeds automatically according to the selected MODE Refer to 14 PROCESS OF EACH MODE At this time to do...

Страница 18: ...AS2 Set the proper time according to the size of vacuum bag the type of packed object packing purpose and pressure degree of GAS SEALING Set the proper time according to the type and thickness of vacu...

Страница 19: ...le moves back Sensor 4 turns on 2nd going down Sensor 3 turns on Then Sealing works as long as preset sealing time Cooling works as long as preset cooling time Sealing bar goes up Sensor 1 turns on an...

Страница 20: ...bar goes up Sensor 1 turns on and 1st work completes 1 If all of Vacuum 1 Vacuum 2 Gas 1 and Gas2 are set at 0 the machine does not operate 2 If you want to do just no other work but gas flushing plea...

Страница 21: ...ng time Cooling works as long as preset cooling time Sealing bar goes up Sensor 1 turns on and 1st work completes 14 4 End of operation 10 Push the STOP button on control box Then the nozzle moves bac...

Страница 22: ...d pull out NOZZLE 15 To clean the nozzle Put compressed air into NOZZLE or put NOZZLE in warm water for a while and then wash its inside 16 To assemble the nozzle Do the reverse of 1 At this time by u...

Страница 23: ...urn the dust kit to the left counterclockwise and separate it At this time pay attention not to lose the rubber ring which is stuck on the upper side of dust kit 2 To clean vacuum filter Get rid of an...

Страница 24: ...same as Article 1 separate heat wire and change existing tape with new one At this time get rid of any particle on the place where tape was stuck When any particle is on there sealed surface is to be...

Страница 25: ...SEALING BAR 10 HEAT WIRE 3 HEATER HOLDER COVER 11 TEFLON TAPE 4 HEATER HOLD 12 BOLT TO FIX HEAT WIRE 5 LOWER SPONGE BAR 13 LOWER TEFLON SHEET 6 UPPER SPONGE BAR 14 UPPER TEFLON SHEET 7 N A 15 SEALING...

Страница 26: ...26 17 LAY OUT DRAWING The real shape and size including frame sealing bar and work tray etc can be changed according to the model and options 17 1 AZ type...

Страница 27: ...27 17 2 AZV type...

Страница 28: ...28 18 INSIDE DRAWING 18 1 AZ type...

Страница 29: ...e 6 Vacuum filter 7 Gas cock 8 Gas valve 9 Fuse holder plate 10 Electricity inlet 11 N F B 12 Air solenoid 13 SSR 14 Grip 15 Control box 16 2P connector 17 Heat wire holder 18 Nozzle cylinder Sensor 4...

Страница 30: ...30 18 2 AZV type 17 Upper body In the case of AZV type the parts including 2 4 6 9 and 10 on the drawing of AZ type are moved to the sub box 18 Sub box...

Страница 31: ...31 Please understand there could be changes of parts according to the model and option...

Страница 32: ...32 19 ELECTRICITY CIRCUIT DIAGRAM According to model and option main and heater fuse type can be changed to 30 A or 40A 19 1 AZ type...

Страница 33: ...33...

Страница 34: ...34 19 2 AZV type...

Страница 35: ...35 19 220 1Ph...

Страница 36: ...36 20 220 3Ph...

Страница 37: ...37 21 380 3Ph...

Страница 38: ...ke action 1 Check up whether AIRZERO AZ appears on LCD screen If not Check up whether compressed air is supplied rightly Refer to 8 5 But if so 2 Check up whether FOOT S W is all right Refer to the fo...

Страница 39: ...y after the upper sealing bar has done 1st going down 1 Check up whether SEALING TIME COOLING TIME and AIR PRESSURE are set properly Refer to 8 5 and 13 If so 2 Check up whether the nozzle correctly i...

Страница 40: ...IR PRESSURE are set properly Refer to 8 5 and 13 If so 2 Check up whether Teflon Sealing Rubber and Heating Element are all right If not exchange it with a new one 20 8 If the heat wire is easily cut...

Страница 41: ...1 in the middle of beginning point and ending point where sensor turns ON If this setting is completed AIRZERO AZ appears on LCD 21 3 Press the MODE button to V and step on FOOT S W Then the nozzle mo...

Страница 42: ...at the time a claim for warranty service is made to the seller under this Limited Warranty THIS LIMITED WARRANTY AND ANY IMPLIED WARRANTIES THAT MAY EXIST UNDER INTERNATIONAL LAW APPLY ONLY TO YOU AS...

Страница 43: ...r or a designated seller s Customer Support center in the original or equivalent packaging with shipping charges except shipping related charges occurred within your local country collect and assume t...

Страница 44: ...OF EQUIPMENT AND PROPERTY AND ANY COSTS OF RECOVERING REPROGRAMMING OR REPRODUCING ANY PROGRAM OR DATA STORED IN THE PRODUCT EVEN IF THE SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOM...

Отзывы: