RAD-Galaxy User’s Guide
56
© 2016 Intrepid Control Systems, Inc.
Version 1.2 - November 28, 2017
version will be shown in red to help you notice that an update is available, as seen in Figure 60
(as well as Figure 58). Section 4.2
provides more information on firmware updates.
There are three buttons on this screen.
Manual Reflash
was described in Section 4.2. The
Read RTC
button will reload the device’s internal time clock, while
Synchronize RTC
will set
the device’s clock to the same value as that of the PC.
Product Details
This is an informational area that provides technical data on the RAD-Galaxy’s hardware and
internal setup. You will generally only need this if requested by Intrepid in order to facilitate
support or troubleshooting. You can use the
Copy To Clipboard
button to copy all of the
information to the Windows Clipboard, so you can then paste it into an email or file.
4.4 Standard CAN Networks (HS CAN 1-5 and MS CAN)
This area of neoVI Explorer is used to enable, disable and configure the six standard dual wire
CAN networks in the FIRE 2: High Speed CAN channels 1 to 5 (HS CAN and HS CAN2-5)
and the Medium Speed CAN channel (MS CAN). Each channel has an entry under the “CAN”
group (which cannot be clicked itself). The current status of each channel is shown next to
its name; a green checkmark indicates that the channel is enabled, while a red X means it is
disabled. Figure 61 shows an example of the CAN channels area, with MS CAN and HS CAN4
currently disabled, and the other channels enabled.
Figure 61: neoVI Explorer CAN Group.
All six of these channels have the same parameters, which can be configured using the
controls in the right-hand pane; the default settings are shown in Figure 62.
Figure 62: neoVI Explorer Standard CAN Parameters with Default Settings.