Page 2 / 6
Page / Fitting and user guide for the EEN-REC3
V233-0013-AA receiver
Anti-passback operation
Anti-passback controls the receiver's 2 ENTRY and EXIT doors to prohibit successive entries
(entries by several vehicles using the same remote control). The resident must therefore have left via
the EXIT door before again being allowed access to the car park via the ENTRY door.
The anti-passback function works by setting an anti-passback time during which any new attempt to
gain access via the ENTRY door is systematically denied. Access via the ENTRY door will be
authorised again, either after this time has expired, or once the resident has left via the EXIT door.
The anti-passback function is only activated with the combined use of:
-
An EEN-REC3 receiver;
-
A GSM Edge DATA unit
-
Vehicle detection loops on ENTRY and EXIT.
And it only works with remote controls to which anti-passback apply (see Website).
This function does not concern any remote controls not programmed to work with the anti-passback
function.
Note: The anti-passbacks are reset on each power up.
The Switches and the LED
•
Switches 1, 2 and 3 define the time of the anti-passback function (+ or - 2 minutes):
S1
S2
S3
Meaning
OFF
OFF
OFF
No anti-passback handling.
ON
OFF
OFF
Anti-passback set to 5 minutes.
OFF
ON
OFF
Anti-passback set to 10 minutes.
ON
ON
OFF
Anti-passback set to 15 minutes.
OFF
OFF
ON
Anti-passback set to 30 minutes.
ON
OFF
ON
Anti-passback set to 45 minutes.
OFF
ON
ON
Anti-passback set to 60 minutes.
ON
ON
ON
Permanent anti-passback.
•
Switches 4 and 5 define the operation of the vehicle detection loops :
S4
S5
Meaning
OFF
OFF
Normally Closed loop (NC) or no loop fitted.
ON
ON
Normally Open loop (NO)
•
Switch no. 6: It must always be set to OFF.
Any action on this switch resets the rolling and anti-passback codes.
•
LED: The LEDindicates the operating states as follows:
State
Meaning
Flashing for 1 to 2 sec
Power supply on or
after switch of switch 6: Erasure of anti-passback and rolling code.
Permanently OFF
The receiver has no power supply: Check the connection to the receiver's
+ and - terminals.
Flickering
The central unit is not connected correctly to the receiver's D + and D-
terminals.
Permanently ON
Correct communication with the central unit: Diagnosis displays "RF".
Goes off for 1 second
Correct reception of the RF emission by a 868 MHz remote control.