Electrical installation
5
j
| BA 14.0190 - EN | 02/2007
26
Type
Input voltage U
1
(40 Hz ... 60 Hz)
Max. current I
max.
Overexcitation time t
o
(
±
20%)
min.
[V
∼
]
rated
[V
∼
]
max.
[V
∼
]
bridge
[A]
half-wave
[A]
with U
1min
[s]
with
U
1rated
[s]
with U
1max
[s]
BEG-561-255-030
160
230
255
3.0
1.5
0.430
0.300
0.270
BEG-561-255-130
1.870
1.300
1.170
BEG-561-440-030-1
230
400
440
1.5
0.75
0.500
0.300
0.270
BEG-561-440-130
3.0
1.5
2.300
1.300
1.200
5.1.2
Reduced switch-off times
When switching on the DC side (reduced switch-off times), switching on the AC side is also
required! Otherwise, there will be no overexcitation during power-on.
Normal switch-off times
Reduced switch-off times
1
2
3
4
6
5
1
2
3
4
6
5
Mains
Bridge
Coil
5.1.3
Permissible current load - ambient temperature
-20 10 20 40 60 80 100
0
0.2
0.4
0.6
0.8
1.0
1
2
I
Imax.
amb [°C]
ϑ
➀
For screw assembly with metal surface (good heat dissipation)
➁
For other assembly (e.g. glue)