Technical specifications
INTORQ | BA 14.0217 | 09/2019
29
5.5
Switching times
The switching times listed here are guide values which apply to DC switching with rated air gap s
LN
, warm
coil and standard characteristic torque. The switching times given are mean values and subject to vari-
ations. The engagement time t
1
is approximately 8 to 10 times longer for AC switching. ...
t
t
M
t
2
t
12
t
11
t
1
M
dyn
U
0.1M
dy
n
Fig. 4:
Operating/switching times of the spring-applied brakes
t
1
Engagement time
t
11
Delay time during engagement
t
2
Disengagement time (up to M = 0.1 M
dyn
)
t
12
Rise time of the brake torque
M
dyn
Braking torque at a constant speed of rotation
U
Voltage
Size
Rated torque
Operating times
1)
DC-side engagement
Disengaging
M
K
t
11
t
12
t
1
t
2
[Nm]
[ms]
[ms]
[ms]
[ms]
06
4
15
13
28
45
08
8
15
16
31
57
10
16
28
19
47
76
12
32
28
25
53
115
14
60
17
25
42
210
16
80
27
30
57
220
18
150
33
45
78
270
20
260
65
100
165
340
25
400
110
120
230
390
Tab. 9:
Switching energy - operating frequency - switching times
1)
These switching times are specified for usage of INTORQ bridge/half-wave rectifiers and coils with a connection
voltage of 205 V DC at s
LN
and 0.7 I
N
.