- 3 - 

1.1.8

 

Protection against freezing of the whole heating system. 

1.1.9

 

Closes by force the mixed valve in systems equipped with a room thermostat, despite 
of its command in case the heating water exceeds its maximum assignation.  

1.1.10

 

Controls  the  mixed  valve  in  relation  to  the  room  thermostat.  The  room  thermostat 
option can be switched off, for example concerning large and multi-circuits systems. 

1.1.11

 

Provides a domestic hot water preparation in a winter and a summer mode in relation 
to the domestic hot water thermostat or timer. 

1.1.12

 

Possibility for adjusting a priority, concerning domestic hot water preparation: 

 

Same one with the heating of the premises or 

 

Higher one by stopping the premises heating. 

The customer is to adjust one of those two priorities. 

1.1.13

 

Control a circulation pump, an actuator or a magnetic valve in the domestic hot water 
circuit. 

1.1.14

 

Automatically goes into a summer mode if the room thermostat or the sensor after the 
mixed  valve  (“O”)  does  not  send  a  command  for  a  start  in  a  period  adjusted  by  the 
customer of 12, 24, 36 or 48 hours after the last command is being sent. 

1.1.15

 

The  main  distinguish  of  the  summer  mode  is  that  the  boiler  cannot  be  started  if  the 
return water temperature of the boiler is lower than the settled one T

kset

, as circulation 

pumps P1 and P2 are switched off. 

1.1.16

 

Automatically  goes  into  a  winter  mode  if  a  command  of  the  room  thermostat  is 
available  or  if  the  heating  water  temperature  (measured  by  sensor  O)  is  lower  than 
Thset. 

1.1.17 STOP mode can be fulfilled by the controller in two ways: automatically with the fuel 
run out or manual, indication about which appears on the display  (fig.2) . Going back to the 
previous mode is to be done only manually. 

 

1.1.18

 

Periodically  starting  the  circulation  pump  in  the  heating  circuit  and  the  mixed  valve 

during summer and STOP mode in order to prevent their blocking after a long stop.

 

1.1.19

 

Manual assignation of the heating water temperature.  

1.1.20

 

Timer and a weekly programmer for an economic operation programming.  

 
On figure 1 is shown functional heating systems, managed by the controller. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Figure 1 

  

K

   

М 

SV 

P2 

RТ 

Boiler 

Controller 

Start 
Stop 

P1 

А 

Water 
Heater 

P3 

Содержание Dynamic Boiler Controller

Страница 1: ...t 00359 898 606 796 f 00359 596 325 80 info intiel com www intiel com 9 Peter Beron Str Pomorie 8000 Bulgaria 1 INTIEL THE ELECTRONICS ON YOUR SIDE Dynamic Boiler Controller User s Manual...

Страница 2: ...r which is being managed by the domestic hot water thermostat installed in the water heater or in the accumulating reservoir where also can be added a timer switch The Controller provides the heating...

Страница 3: ...tat or the sensor after the mixed valve O does not send a command for a start in a period adjusted by the customer of 12 24 36 or 48 hours after the last command is being sent 1 1 15 The main distingu...

Страница 4: ...best results can be achieved by using proportional thermostat with an integration control of the temperature The precision class of the used room thermostat directly affects to the precision in keepi...

Страница 5: ...low heating water temperature bellow 5 and fuel presence the boiler and pumps are being switched on as the valve starts opening in order to prevent freezing light indication 8 is being activated figur...

Страница 6: ...dication for return temperature water decreasing bellow the assigned value 7 Control indication showing exceeded emergency outlet boiler temperature 8 Control indication showing very low heating water...

Страница 7: ...ch the heating water temperature has a maximum value Tou min see point 1 5 5 1 With temperatures below 20 and above 120 instead of values are being indicated low and hi To enter the main menu button S...

Страница 8: ...e settings restore the default settings Test actuator it is being used for a control of correct wiring connection of the actuator Press SET button in order to make some changes By means of button it i...

Страница 9: ...oiler outlet temperature exceeds the assigned one the Controller indicator 7 Figure 3a will light the boiler will stop by force the mixed valve will be open and the circulation pumps P1 and P2 will st...

Страница 10: ...e can be constant or it can be defined in relation to the outdoor temperature Thus there is no cooling of the radiators during penetrating of a cold air through the windows towards the floor If such f...

Страница 11: ...assigned one The previous mentioned could happen if the outlet boiler temperature reaches its emergency value and the Controller has been opened the mixed valve 1 5 5 1 Selection of the lower border o...

Страница 12: ...0 2 Installation of the Controller 2 1 Introduction The installation of the Controller must be done by a qualified staff The connection of the boiler the mixed valve servo actuator and the circulation...

Страница 13: ...sor of the return boiler water V together with the sensor of the outlet water temperature K and in the same time setting up the minimal temperature of the return water at 650 C In this way the outlet...

Страница 14: ...h its resistance that can reach 100 The room thermostat location is something very important It is suitable the thermostat to be placed at the most occupied room in the house that will become a standa...

Страница 15: ...domestic hot water circuit are shown at Figure 7 a With four way mixed valve and third circulation pump for domestic hot water circuit Figure 7a b With four way mixed valve and three way magnet valve...

Страница 16: ...the domestic hot water timer is being switched on by time while the premises heating is being provided opned mixed valve so the Controller will send a signal for a complete mixed valve closing in ord...

Страница 17: ...lower than 60 the boiler fan operates constantly and it is managed by means of the room or outdoor thermostat During smooth increasing of the boiler temperature above 60 for example when the valve is...

Страница 18: ...terminals X16 This contact is being opened in case of boiler overheating If an emergency thermostat is not provided so terminals X16 are to be connected in a short circuit by means of outer electrical...

Страница 19: ...tion 6 appears and the servo actuator starts closing the boiler water flow to the heating circuit The recommended levels of the fixed return boiler water temperature are as follows Boilers with steel...

Страница 20: ...er activating the first stage the boiler would not be stopped by the working thermostat neither to be able to reach the assigned boundary level of the outlet boiler temperature That means the lowest p...

Страница 21: ...use Regarding faster actuators it is to be fixed less operation time and vice versa The default setting is 20 3 1 8 Control of the domestic hot water thermostat operation If no one of the indications...

Страница 22: ...rcuit in the sensor or temperature bellow 300 C The sensor is to be replaced The premises cannot be heated to the desired temperature Low temperature of the boiler water Increase the assignation of th...

Страница 23: ...inary adjusted with most of the room thermostats For example it can be a not freezing temperature that is adjusted to most of the room thermostats Then to go back to winter mode is enough to get back...

Страница 24: ...water tank temperature 30 80 60 Thermost at st1 Operation thermostat assignation of 1st burner stage 75 90 85 Thermost at st2 Operation thermostat assignation of 2nd burner stage 60 75 65 Outdoor temp...

Страница 25: ...nths after the production date The warranty is extended to the malfunctions that occur during the warranty period and are result of the production reasons or defective used parts The warranty does not...

Отзывы: