background image

128

GS

SAVE THESE INSTRUCTIONS

Page 17

(128GS)  MODEL SF20220R SAND FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  10/28/2011

English

1.

Switch off the unit, and disconnect power cord from electrical outlet.

2.

In a counter clockwise motion unscrew the drain valve cap 

(9) 

from the drain 

valve to thoroughly drain the tank. The drain valve is located at the bottom of 
the  filter tank. 

3.

Disassemble the pump motor from the tank base.

4.

Leave sand filter pump pieces and hoses outside to thoroughly air dry.

5.

Coat the following o-rings and washers with petroleum jelly for long term 
storage:
• L-shape o-ring 

(11).

• o-ring A 

(18).

• Pump hose O-rings 

(22)

.

• Strainer valve assembly step washers 

(23)

.

• Flat strainer rubber washers 

(25)

.

6.

Depress the 6-way valve handle and rotate so as to set the pointer on the valve 
top  “N” position. This allows the water to drain from the valve. Leave the 6-way 
valve in this inactive position.

7.

It is best to place all dry pieces and pump motor in the original packaging for 
storage. To avoid condensation or corrosion problem, do not cover or wrap 
pump motor with plastic bags.

8.

Store the pump motor and accessories in a dry place. The storage's 
temperature should be controlled, between 0 degrees Celsius (32 degrees 
Fahrenheit) and 40 degrees Celsius (104 degrees Fahrenheit).

LONG TERM STORAGE & WINTERIZATION

CAUTION

Allowing the water to freeze will damage the sand filter and void the 
warranty.  If anti-freeze solution is needed, use only propylene glycol.
Propylene glycol is non-toxic and will not damage plastic system 
components; other anti-freezes are highly toxic and may damage plastic
components in the system.

MM

AA

IINN

TT

EE

NN

AA

NN

CC

EE

Содержание SP20220

Страница 1: ...roits réservés Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprimé en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilisées dans certains pays sous licence de Marcas registradas utilizadas en algunos países del mundo bajo licencia de Warenzeichen verwendet in einigen Ländern der Welt in Lizenz von Int...

Страница 2: ...NTONE 295U 10 28 2011 English T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S Warnings 3 Parts List References 4 6 Setup Instructions 7 11 Product Specifications 7 Operating Instructions 12 14 Maintenance 15 Troubleshooting Guide 16 Limited Warranty 17 Intex Service Center Locations 18 ...

Страница 3: ...quipment If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water...

Страница 4: ...0220R SAND FILTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 10 28 2011 English P P A A R R T T S S L L I I S S T T PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale 7 1 9 4 5 2 6 3 8 10 11 13 14 15 16 17 18 19 12 20 21 ...

Страница 5: ...LTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 10 28 2011 English PARTS LIST continued NOTE Drawings for illustration purpose only Actual product may vary Not to scale 23 25 22 24 26 27 28 29 30 31 32 33 34 Optional Optional Optional 35 P P A A R R T T S S L L I I S S T T ...

Страница 6: ... P A A R R T T S S R R E E F F E E R R E E N N C C E E PARTS REFERENCE Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 1 5 9 11 2 13 35 19 3 6 7 4 15 16 17 11 18 8 10 14 36 37 38 ...

Страница 7: ... RING 4 11228 12 HOSE WITH NUTS 2 11010 13 SAND FILTER INTERCONNECTING HOSE 1 11535 14 LEAF TRAP NUT 1 11479 15 LEAF TRAP O RING 1 11232 16 BASKET 1 11260 17 FILTER HOUSING NUT 1 11261 18 L SHAPE O RING 1 11412 19 SEDIMENT RELEASE VALVE 1 10460 20 VALVE O RING 1 10264 21 PLUNGER VALVE HOSE O RING STEP WASHER INCLUDED 2 10747 22 HOSE O RING 2 10262 23 STEP WASHER 2 10745 24 STRAINER NUT 2 10256 25 ...

Страница 8: ...s a specialized area and you should consult your local pond service specialist for details TOOLS REQUIRED One 1 Phillips screwdriver Pump location and mounting The system must be installed on a solid level and vibration free base Provide a location protected from the weather moisture flooding and freezing temperature Provide adequate access space and lighting for routine maintenance Pump motor req...

Страница 9: ...ly unit to the tank support base See drawing 5 2 NOTE Ensure the pre filter housing water inlet hose connection is facing towards the pond IMPORTANT Some countries especially in the European community require the product to be secured to the ground or to a base in a permanent upright position Check your local authorities to determine if there is a regulation in your area regarding pond filter pump...

Страница 10: ...e the sand shield 6 over the top of the center pipe Pour the sand into the tank at a slow rate see drawing 6 2 Fill the tank approximately half way remove the sand shield 6 from the top see drawing 7 3 Evenly distribute the sand inside the tank then fill the tank with some water to provide a cushioning effect when the remaining sand is poured in This prevents the center pipe hub 7 from excessive s...

Страница 11: ...ith the motor outlet see drawing 11 S S E E T T U U P P I I N N S S T T R R U U C C T T I I O O N N S S SETUP INSTRUCTIONS continued WARNING Improper tank valve and clamp assembly could cause the valve and clamp to blow off and cause serious injury property damage or death 11 WATER INLET WATER OUTLET 2 Place an L shape o ring 11 on the 6 way valve inlet connection and on the pump motor outlet In a...

Страница 12: ...r Ensure the hose nuts are securely tightened 2 Connect the second hose between the 6 way valve water outlet and the upper plunger valve with the inlet nozzle Ensure the hose nuts are securely tighten 3 The third hose connection port drain waste outlet on the 6 way valve shall be directed to a proper draining receptacle using a hose or pipe not provided Remove the drain cap before attaching the dr...

Страница 13: ...ter Flow Direction FILTER see drawing 14 Normal filtration and regular vacuuming of pond From pump through filter media to pond BACKWASH see drawing 15 Reverses water flow to clean filter media From pump through filter media to valve waste drain outlet RINSE see drawing 16 For initial startup cleaning of the sand and leveling the sand bed after backwashing From pump through filter media to valve w...

Страница 14: ... drawings 15 20 IMPORTANT To prevent damage to the 6 way valve always depress the valve handle before turning Always switch off pump before changing the 6 way valve position 4 Switch on the pump see drawing 21 Water is circulating backward through the sand media and to waste drain outlet Backwash until a clear flow of water is observed in the waste drain outlet or through the drain sediment window...

Страница 15: ... flow to diminish If there is no vacuuming device attached to the system and the pressure gauge reading is in the yellow zone it is time to backwash the sand media see BACKWASH under initial startup and operation section Vacuuming device i e Intex auto pond cleaner attached to the system may also cause the flow to diminish and the pressure to rise Remove any vacuuming device from the system and ch...

Страница 16: ... on the lower side of the pre filter housing see drawing 23 3 In a counter clockwise motion unscrew the leaf trap cover 14 then remove the basket 16 and leaf trap o ring 15 from the pre filter housing see drawing 24 4 Empty and flush the basket using a garden hose may use a plastic brush to remove deposits from the basket Do not use metal brush 5 Clean and rinse the inside of the pre filter housin...

Страница 17: ...handle and rotate so as to set the pointer on the valve top N position This allows the water to drain from the valve Leave the 6 way valve in this inactive position 7 It is best to place all dry pieces and pump motor in the original packaging for storage To avoid condensation or corrosion problem do not cover or wrap pump motor with plastic bags 8 Store the pump motor and accessories in a dry plac...

Страница 18: ...ions in the intake by unscrewing it from the 6 way valve Contact Intex service center Use only No 20 silica sand with particle size range 0 45 to 0 85 mm 0 018 to 0 033 inches and a Uniformity Coefficient less than 1 75 Change sand FILTER MOTOR FAILS TO START FILTER DOESN T CLEAN POND FILTER DOESN T PUMP WATER OR FLOW IS VERY SLOW PUMP DOESN T WORK 6 WAY VALVE COVER LEAKING HOSE LEAKING TIMER IS I...

Страница 19: ... contact the appropriate Intex Service Center listed in this manual The Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES OR LIABILITIES Some countries or jurisdictions do not allow the excl...

Страница 20: ... ANTONIO SÃO PAULO SP BRASIL TEL 55 11 5181 4646 FAX 55 11 5181 4646 E mail sacintexbrasil uol com br ISRAEL ALFIT TOYS LTD MOSHAV NEHALIM MESHEK 32 49950 ISRAEL TEL 972 3 9076666 FAX 972 3 9076660 E mail michald chagim co il ASIA INTEX DEVELOPMENT CO LTD 9TH FLOOR DAH SING FINANCIAL CENTRE 108 GLOUCESTER ROAD WANCHAI HONG KONG TEL 852 28270000 FAX 852 23118200 E mail xmservicesupport intexcorp co...

Отзывы: