background image

133

(133) MODEL CS8111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 11/17/2011

English

OOWW

NNEE

RR’’

SS  

MM

AANN

UUAA

LL

Krystal Clear

Saltwater System

®

& Filter Pump

Model CS8111

IMPORTANT 

SAFETY RULES

Read, understand, and follow all

instructions carefully before

installing and using this product.

IIM

MPPOORRTTAANNTT!!

DO NOT RETURN PRODUCT TO STORE

To purchase parts and accessories or to obtain non-technical assistance,

Visit www.intexcorp.com

For technical assistance and missing parts call us toll-free (for U.S. and Canadian Residents):

1-800-234-6839

Monday through Friday, 8:30am to 5:00pm Pacific Time

Don’t forget to try these other fine Intex products: pools, pool accessories,

inflatable pools and in-home toys, airbeds and boats available at fine

retailers or visit our website.

133-***-R1-1211

For illustrative purposes only. 

Содержание Saltwater System CS8111

Страница 1: ...MP PO OR RT TA AN NT T DO NOT RETURN PRODUCT TO STORE To purchase parts and accessories or to obtain non technical assistance Visit www intexcorp com For technical assistance and missing parts call us...

Страница 2: ...ons 11 14 Salt Pool Water Volumes 15 Intex Pools Salt Table 16 Intex Pools Operating Time Table 17 Intex Pools Cyanuric Acid Table 18 Non Intex Pools Salt Table 19 Non Intex Pools Operating Time Table...

Страница 3: ...uct The unit is provided with a ground fault circuit interrupter GFCI To test the GFCI push the test button The GFCI should interrupt power Push the reset button power should be restored If the GFCI f...

Страница 4: ...111 SALTWATER SYSTEM FILTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 11 17 2011 English P P A A R R T T S S L L I I S S T T PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary N...

Страница 5: ...ENGLISH 7 5 X 10 3 PANTONE 295U 11 17 2011 English 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 PARTS LIST continued P P A A R R T T S S L L I I S S T T NOTE Drawings for illustration purpose only Ac...

Страница 6: ...mpliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules The...

Страница 7: ...R RELEASE VALVE B WITH O RING PUMP HOSE WITH NUTS WATER TRANSFER HOSE WITH COLLAR AND 2 HOSE CLAMPS SCREW FLOW SENSOR O RING A ELECTROLYTIC CELL WITH 2 SCREWS O RING A INCLUDED COPPER ELECTRODE FLOW S...

Страница 8: ...T T S S R R E E F F E E R R E E N N C C E E PARTS REFERENCE continued Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawing...

Страница 9: ...11072 11131 19635 11254 QTY 2 2 2 2 1 2 2 1 1 1 1 1 DESCRIPTION PLUNGER VALVE HOSE O RING STEP WASHER INCLUDED HOSE O RING STEP WASHER STRAINER NUT FLAT STRAINER RUBBER WASHER THREADED STRAINER CONNEC...

Страница 10: ...er flows through the saltwater system s electrolytic cell to produce HCLO The HCLO dissolves in the water and instantly starts destroying bacteria and algae It also oxidizes all other organic material...

Страница 11: ...p rubber washer 21 3 Grasp the plunger valve assembly Make sure the step washer 21 is in place Connect adaptor B 26 to plunger valve union 4 Repeat steps 1 through 3 for nozzle and plunger valve mecha...

Страница 12: ...iner and plunger valve at the lower position of pool outlet marked From the inside of the pool liner insert the connector 24 into one of the pre cut holes with the washer remaining on the connector to...

Страница 13: ...Then with the flat side of the strainer nut 22 facing the outside wall of the liner in a clockwise motion screw the strainer nut 22 back onto the threaded connector 24 see drawing 6 6 Finger tighten t...

Страница 14: ...is an airtight system In a counter clockwise motion turn both air release valves 1 7 1 2 turns to open DO NOT remove air release valves as water will expel with force if the motor is turned on and in...

Страница 15: ...om the pool Salt is not lost due to evaporation Adding Salt 1 Switch on the unit then press and hold both and button for 5 seconds the LED flashes FP The unit is now in a Filter pump working mode and...

Страница 16: ...2 549cm x 132cm 20 x 52 610cm x 132cm 24 x 48 732cm x 122cm 24 x 52 732cm x 132cm 16 x 48 488cm x 122cm 18 x 52 549cm x 132cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm x 305cm...

Страница 17: ...x 48 457cm x 122cm 16 x 48 488cm x 122cm 18 x 48 549cm x 122cm 18 x 52 549cm x 132cm 20 x 52 610cm x 132cm 24 x 48 732cm x 122cm 24 x 52 732cm x 132cm 16 x 48 488cm x 122cm 18 x 52 549cm x 132cm 16 8...

Страница 18: ...cm 18 x 52 549cm x 132cm 15 x 36 457cm x 91cm 15 x 42 457cm x 107cm 15 x 48 457cm x 122cm 16 x 48 488cm x 122cm 18 x 48 549cm x 122cm 18 x 52 549cm x 132cm 20 x 52 610cm x 132cm 24 x 48 732cm x 122cm...

Страница 19: ...rtup Lbs Salt Needed for Startup Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 006...

Страница 20: ...ure will allow the air trapped inside to escape from the air release valves 1 7 When all the air has escaped water will flow out of the valves 1 7 When this occurs gently finger tighten the valves in...

Страница 21: ...now activate your Saltwater System at the same time each day for the number of hours you have set NOTE The Saltwater System will not operate if the filter pump is not operating 3 Lock keypad controls...

Страница 22: ...rtant that the free chlorine is between 0 4 1 5 ppm and copper ion concentration is between 0 1 0 2 ppm When the copper level is below 0 1 ppm repeat step 6 NOTE A High copper ion concentration may ca...

Страница 23: ...s 3 hours remaining 04 Operating Hours 4 hours remaining 05 Operating Hours 5 hours remaining 06 Operating Hours 6 hours remaining 07 Operating Hours 7 hours remaining 08 Operating Hours 8 hours remai...

Страница 24: ...hen use a garden hose to wash it off 3 If flushing with water does not remove the deposits use a plastic brush to clean the surface and the hinge if necessary Do not use a metal brush 4 After the flow...

Страница 25: ...from flowing out of the pool 3 Disconnect the hose with nut 8 from the Saltwater System and assemble the cell cover 30 at the side of the cell 4 In a counter clockwise motion unscrew the collar of th...

Страница 26: ...ousing cover 4 6 Now remove the used filter cartridge 7 Examine the inside of the filter housing 8 If dirt or sediment is located on the bottom of the housing then A In a counter clockwise motion gent...

Страница 27: ...immediately 2 Hold the strip level for 15 seconds Do not shake excess water from the strip 3 Now compare the strip pad to the color chart on the packaging label If necessary adjust the chemical level...

Страница 28: ...ion is Result if too low Corroded metals eye skin irritation destruction of total alkalinity Result if too high Scale formation cloudy water shorter filter runs eye skin irritation poor Chlorine effic...

Страница 29: ...outlet that is protected by a Class A Ground Fault Circuit Interrupter or RCD Reset circuit breaker If circuit breaker trips repeatedly your electrical system may have a defect Turn off circuit breake...

Страница 30: ...ng Instructions Use PH decrease chemical to adjust contact your local pool chemical store Increase the operating time per day See Operating Instructions Remove the cell for inspection clean it if nece...

Страница 31: ...lter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Check that the arrow on the flow sensor conduit points in the same directio...

Страница 32: ...and around the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as l...

Страница 33: ...disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civ...

Страница 34: ...el 507 300 3800 NICARAGUA Fax 507 300 3813 E mail suproadmin supropanama com COSTA RICA CENTURY USA LLC DOMINICAN REPUBLIC 4731 W Atlantic Ave Suite B 3 GUATEMALA Delray Beach FL 33445 USA COLOMBIA Te...

Страница 35: ...roits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license fr...