254
A
S AVE THESE INSTRUCTIONS
(254IO) SPA ENGLISH 7.5” X 10.3” PANTONE 295U 01/28/2016
English
Page 8
PRODUCT SPECIFICATIONS
SET UP
Cord-connected spa with pump, heater, blower, built-in hard water treatment and control panel.
This product requires a minimum of 13 Amps. If the circuit breaker trips, please check that no other
appliances or other large loads are on the same circuit as the spa.
Site preparation and requirements
• The spa can be installed indoor or outdoor. For household use only.
• Make sure the area is free of sharp objects under or around the spa.
• Provide a properly located power outlet to connect the spa and allow easy access for periodic testing of the
cord mounted RCD.
• Make sure there is enough clearance around the spa for full access to the spa equipment for maintenance
and/or
service.
• The area shall facilitate draining purposes during long term spa storage.
Additional requirements for indoor installation
• Make sure the
fl
oor can support the full weight of the
fi
lled spa with the maximum number of occupants.
Check with a quali
fi
ed contractor or a structural engineer to verify this requirement.
• Make sure the
fl
oor is water resistant and non-slip surface. Do not install the spa on carpet or other
materials that will be damaged by moisture, condensation.
• Do not install the spa indoors on a second
fl
oor above
fi
nished living space due to the possibility of water
and humidity damage.
• Humidity is a natural side effect of indoor spa installation. The room shall be properly ventilated to allow
moisture to escape. Install a ventilating system to prevent excess condensation, moisture in the room.
Additional requirements for outdoor installation
• Spa owners may need to comply with local or states laws relating to childproof fencing, safety barriers,
lighting, and other safety requirements. Contact your local building code enforcement of
fi
ce for further
details.
• Make sure the surface is level,
fl
at, smooth and strong enough to support the full weight of the
fi
lled spa.
• Do not setup the spa on grass or dirt, as this increases the amount of debris entering the spa, and damage
the
spa
fl
oor.
•
Do not expose the spa to direct sunlight for extended period of time.
• It is possible to install and leave the spa outside at a temperature not lower than 4°C (39°F) provided the
water temperature inside the spa is higher than 4°C (39°F) and the water inside the circulation system,
pump, pipe are not frozen. Put a “temp barrier mat” between the spa
fl
oor and the ground to prevent heat
loss from the bottom of the spa and to provide better heat retention.
Maximum seating capacity:
4 adults
6 adults
Water capacity:
210 gal (795 L)
290 gal (1098 L)
Inner/outer diameter:
57/77 in (145/196 cm)
65/85 in (165/216 cm)
Height:
28 in (71 cm)
Bubble air blower:
1.1HP / 220-240 V / 50 Hz
Filter pump
fl
ow rate:
460 gal/hr (1,741 L/hr)
Heater power:
2,200 Watts / 220-240 V / 50Hz
Temperature range:
20ºC – 40ºC (68ºF – 104ºF)
Temperature rise:
1.5-2.5ºC/hr (3ºF – 4.5ºF/hr)
1-2ºC/hr (2ºF – 3.5ºF/hr)
Number of Bubble Jets:
120
140
Spa tub recommended working air pressure:
0.083 bar (1.2 psi)