SAVE THESE INSTRUCTIONS
Page 2
(249PO) MODEL ECO7111 Cartridge Filter Pump & Saltwater System with E.C.O. ENGLISH 7.5” X 10.3” PANTONE 295U 04/06/2017
English
249
PO
S AVE THESE INSTRUCTIONS
English
Page 18
SALTWATER SYSTEM OPERATION (continued)
5.
Boost cycle
•
First time installation, press and hold “BOOST” button for 5 seconds until the
indicator lights up and the LED display “80”. This indicates that the saltwater
system has started E.C.O
.
and more chlorine sanitizer production. You can
press and hold the “BOOST” button for another 5 seconds until the indicator
is off, which will cancel the Boost cycle.
•
The boost operating hours is 8 times the amount of time programmed into the
system, i.e. if your saltwater system operating time is 2 hours, the boost
procedure will run 8 x 2 = 16 hours. After boost procedure has been completed, the system will
automatically switch to the normal working mode.
•
After a heavy rain or if the pool is dirty, press the “BOOST” button to shock the pool again.
6. Stand-by/power saving mode:
•
When the cycle ends, the green “SLEEP” indicator on the control panel lights
up and the LED display flashes “93”. The system is now in Stand-By mode.
After a while, it shuts down and sets itself in a Power Saving mode. The
system will automatically turn itself back on in 24 hours, starting its daily
cycle of chlorine production.
•
The “SLEEP” indicator stays on, while the system is in the Power Saving
mode. The LED display however, goes blank after 5 minutes. Press any
button ( or ) to view the last LED code.
7. Running the pump alone without the Saltwater System:
To run the pump alone without the Saltwater System function, press and hold
both and buttons until you hear a “beep”, the LED display will show
“FP”. The pump is now operating alone. NOTE: The pump cannot be
operated alone under an automatic timer mode. To stop the pump, manually
turn the switch OFF.
To bring back the initial automatic operating cycle setting
of the Saltwater System:
a) If the LED display shows “FP”, press the button and the operating
hours set previously will begin flashing, press the button again or
simply wait 1 minute, and the LED will stay illuminated. The Saltwater
System cycle repeats again.
b) If the unit is OFF, turn the switch ON, the LED display shows “FP”,
press the button and the operating hours set previously will begin
flashing, press the button again or simply wait 1 minute, and the
LED will stay illuminated. The Saltwater System cycle repeats again.