8.

  Resume filling the pool with water to the recommended level.

9.

  Open the water outlet plunger valve or remove the strainer hole plug from the 

outlet fitting.

10.

 Turn on the pump and purge all the air out from the hoses and pump.

Maintenance and Long Term Storage

 

1.

  Regularly check all components for sign of damage, straining. Discard and 

replace damaged components immediately.

2.

  Use a sponge and clean water to wipe away any soil or stains.

3.

  Disassemble the product when the temperature drops below 5°C (41°F) by 

reversing the above setup instructions, drain the water out of the waterfall, and 
make sure all components are completely dry before storage.

4.

  Store the waterfall and accessories in a dry, temperature controlled, between 

0º – 40ºC (32º – 104ºF), storage location.

5.

  The original packing can be used for storage.

TROUBLE

SOLUTION

Light is off / 
fl ashing

•  Make sure the filter pump is operating, the pump water 

return hose is attached to the bypass valve lower port and 
the bypass valve is in the waterfall position (handle pointing 
up). see “Setup” section. 

•  Make sure the connecting hose 

(8)

 is attached between the 

waterfall and the bypass valve left port.

•  Check if the pump system flow rate is within the specified 

range, if the system flow rate is less than 3,596 L/h (950 g/h), 
change pump with higher system flow rate.

•  Clean or replace the filter pump cartridge. If using a sand 

filter, ensure the sand media is clean by backwashing it.

•  Use a garden hose to wash the waterfall opening, check to 

see if any sand or deposits inside the waterfall set.

•  Contact Intex Service Center.

Poor water 
cascade 
performance

 

•  Use a damp cloth to wipe away any dirt on the waterfall 

opening.

•  The performance depends on the filter pump flow rate. If 

you are not satisfied with the water cascade performance,  
a higher flow rate filter pump is recommended. 