(114BS) ELECTRIC POOL HEATER ENGLISH 7.5” X 10.3” PANTONE 295U 08/16/2015
English
114
BS
SAVE THESE INSTRUCTIONS
English
Page 11
TROUBLESHOOTING GUIDE
• Plug in the power cord.
• Switch the knob clockwise to the "I" position
to turn the electric pool heater on.
• Re-plug the GFCI/RCD and press the
“RESET” button.
• The temperature sensor will cut off the
power of heater when the water temperature
is above approximately 95oF (35°C). It
continues to work when the water
temperature drop below approximately 82°F
(28°C).
• Turn on the filter pump.
• Ensure the plunger valves are opened (if
any).
• Ensure your filter cartridges are clear from
debris and dirt.
• Release all trapped air in the circulation line.
• Check for the direction of water inlet and
water outlet hose. Reverse the hose if
necessary.
• Always use the solar cover if the pool is not
occupied.
• Increase the heating time properly.
• Stop the heater and shorten the heating time.
• Tighten/reinstall hose clamps.
• Reposition/replace hose seals.
• Unplug the GFCI/RCD and then re-plug in
and press the “RESET” button to start the
heater. Contact Intex Service Center if it trips
off continuously.
THE RED INDICATOR
DOES NOT LIGHT UP
DURING USE
THE WATER
TEMPERATURE
DOES NOT INCREASE
ALTHOUGH THE RED
INDICATOR IS LIT UP
THE WATER
TEMPERATURE IS TOO
HIGH
HOSE LEAKING
GFCI/RCD KEEPS
TRIPPING OFF
1. The power cord is not plugged in.
2. The knob is not fully switched to on
position – “I”.
3. The GFCI/RCD plug is not turned
on.
4. The water temperature is too high.
5. No water flow.
6. Low water flow.
1. Pool or solar cover not been used.
2. The pool size or water capacity
exceeds the heater capacity.
3. The water temperature is too low.
1. Heating time too long.
1. Hose clamps.
2. Hose seals.
1. Product failure or electrical circuit
problem.
PROBLEM CAUSE REMEDY
IMPORTANT
If you continue to experience difficulty, please contact our Consumer Service
Department for assistance. See separate “Authorized Service Centers” sheet.