SEPAMAT
F_manual_Vers.2.8f_en
19
4.
Close
the
air
vent.
5.
Open
the
pressure
line
shut
‐
off
valve
and
flush
the
air
from
the
consumer
line
(e.g.
by
flushing
the
toilet
several
times
or
opening
the
garden
tap).
6.
Close
all
the
fixtures.
The
pump
will
now
automatically
switch
off
when
the
maximum
system
pressure
is
reached.
7.2
Display
The
green
LED
on
the
pump
controller
indicates
that
the
pump
is
ready
to
use.
In
case
of
a
problem,
the
red
LED
will
light
up
(see
section
5.1).
The
system
pressure
can
be
read
on
the
pressure
gauge
of
the
pump
controller.
The
Automatic
Mode
or
Maintenance
Mode
can
be
set
via
the
mode
selecting
switch.
8
Trouble
‐
shooting
Malfunction
Cause
Solution
Pump
does
not
start
and
the
red
LED
is
on
‐
Pump
shuts
off
after
a
brief
hum
and
the
RESET
‐
Replace
the
capacitor
‐
No
water
in
the
priming
tank
‐
Test
the
mains
water
valve
Pump
switches
on
and
off
continuously
‐
Unsealed,
leaky
fixture
‐
Repair
leak
‐
Minimal
flow
rate
through
the
fixture
(<
1
l/min)
‐
Test
the
fixtures
(for
several
small,
connected
fixtures,
an
expansion
vessel
is
suggested
to
reduce
switch
on
‐
switch
off
rate)