background image

 

 

SEPAMAT

 

F_manual_Vers.2.8f_en

 

18

 

 

7

 

Start

up

 

and

 

use

 

 
 

7.1

 

Start

up

 

in

 

mains

 

water

 

mode

 

1.

 

Open

 

the

 

mains

 

water

 

line

 

stopcock

 

so

 

that

 

the

 

supply

 

container

 

is

 

filled

 

with

 

water.

 

Note:

 

In

 

maintenance

 

mode

 

the

 

pump

 

primed

 

with

 

water

 

automatically

 

over

 

the

 

mains

 

water

 

tank.

 

In

 

this

 

case

 

the

 

pump

 

cannot

 

be

 

manually

 

filled

 

with

 

water!

 

 

 

 

2.

 

Close

 

the

 

pressure

 

line

 

shut

off

 

valve.

 

 
 

 

 

3.

 

Open

 

the

 

air

 

vent

 

(hold

 

a

 

bucket

 

of

 

water

 

under

 

the

 

air

 

vent)

 

and

 

start

 

the

 

pump

 

by

 

plugging

 

in

 

the

 

mains

 

power.

 

Let

 

the

 

water

 

run

 

from

 

the

 

air

 

vent

 

into

 

the

 

water

 

bucket

 

until

 

there

 

is

 

no

 

more

 

sign

 

of

 

bubbles

 

(a

 

clear

 

stream)

 

meaning

 

that

 

all

 

air

 

has

 

been

 

removed

 

from

 

the

 

suction

 

line.

 

 

 

 

 

Содержание SEPAMAT F

Страница 1: ...WATER WE RE IN OUR ELEMENT www intewa com SEPAMAT F Installation and user manual...

Страница 2: ...9 5 1 Components of the pump controller 9 5 2 Components of the basic controller 10 5 3 Components of the multistage pump 12 5 4 Components of the supply container 13 6 Installation instructions 14 6...

Страница 3: ...protects drinking water against contamination caused by backflow of pollutants from the consumer point of use System separation is installed between the municipal drinking water supply and one or more...

Страница 4: ...ns at the mains water pipeline system have to be only performed by a qualified installation company A floor drain has to be provided near the installation site which can collect inadvertent water disc...

Страница 5: ...T F_manual_Vers 2 8f_en 4 3 Scope of delivery Separation unit SEPAMAT F Wall mounting material installation and user manual Standard accessory A Mains water connection Standard accessory B Pressure li...

Страница 6: ...current 4 A 5 8A Motor capacitor 12 5 F 20 F Max discharge pressure 4 5 bar 5 5 bar Max flow rate 80 l min 110 l min Noise level ca 60 dBA ca 65 dBA Pump start up pressure 1 0 2 2 bar adjustable facto...

Страница 7: ...l pump SEPAMAT F20 40 2 Pump terminal box with basic controller 3 Vent cock 4 Pressure line shut off valve 3 4 female 5 Pump controller 6 Supply container 7 Stopcock for mains water 3 4 female 8 Mains...

Страница 8: ...secure separation of processed water from the mains water line which is integrated into the SEPAMAT F 4 1 2 3 Mains water separation device Type AB as per DIN EN 1717 Certification separation device a...

Страница 9: ...mity with the relevant Union harmonization legislation 2006 42 EU Maschinenrichtlinie 2006 42 EU Directive Machinery 2014 30 EU EMV Richtlinie 2014 30 EU Directive relating to electromagnetic compatib...

Страница 10: ...is recommended that only experienced professionals use the pressure setting option The pump start up pressure is set to 1 5 bar by default That means the pump switches on when the system pressure fall...

Страница 11: ...troller year of manufacture from 04 2021 5 2 Components of the basic controller The basic controller will be found in the terminal box of the pump 1 where all the electrical components of the SEPAMAT...

Страница 12: ...r brown N Pump controller blue Pump controller black N Pump blue L1 Pump brown 12 13 14 15 16 17 18 19 20 21 22 SS PE PU PE LP PE NE br SS brn SS bl KH schw KH gr n KH rt LP bl LP brn free Protective...

Страница 13: ...CAPACITOR 47 CAPACITOR ZBR 1 ZBR 1 pcs 16 16 O RING NOZZLE 1 pc 1 84 84 PLUG FRONT 1 pc 1 88 88 SHUTTER 1 pc 1 490 490 RUBBER SPACER 1 pc 1 89 89 SPRING SHUTTER 1 pc 1 370 370 SELF PRIMING SUCTION 1 R...

Страница 14: ...rizontal lever is factory set at 85 mm by the SMT 20 float valve and 90 mm by the SMT40 float valve Note If an overflow occurs due to continuous dripping from the valve the valve must be decalcified s...

Страница 15: ...is mounted on a wall with the supplied wall bracket The lid and lateral distances indicated should be adhered to when mounting to provide clear maintenance access The SEPAMAT F is wall mounted in suc...

Страница 16: ...ose and stopcock Screw the gland screw into the container connection and carefully tighten with a fixed wench Note The flexible hose must not be overtightened as this may interfere with the internal f...

Страница 17: ...line set is connected to the pump controller The flexible hose and the shut off valve then connect to the pressure line set and the pressure line 6 4 Connecting the emergency overflow The SEPAMAT F ha...

Страница 18: ...entering the SEPAMAT F The position of the backwater level determines the type of line a Backwater level above the emergency overflow drainage height of the supplemental supply container Connection of...

Страница 19: ...automatically over the mains water tank In this case the pump cannot be manually filled with water 2 Close the pressure line shut off valve 3 Open the air vent hold a bucket of water under the air ven...

Страница 20: ...l light up see section 5 1 The system pressure can be read on the pressure gauge of the pump controller The Automatic Mode or Maintenance Mode can be set via the mode selecting switch 8 Trouble shooti...

Страница 21: ...aphragm chamber as well 24 hours exposure time If the dripping continues after maintenance then the valve must be replaced 10 Spare parts Description Figure No see section 4 1 Bestellbezeichnung Multi...

Страница 22: ...tails at INTEWA GmbH Auf der H ls 182 52068 Aachen Tel 0049 241 96605 0 Fax 0049 241 96605 10 Email info intewa de Internet www intewa de For customers in other countries For any queries ordering of s...

Отзывы: